8-4 Robot Language Description

8
6
8-
8-4
Robot Language Description

8-4-1 MOVA

Function:
Format:
Example:
Explanation:

8-4-2 MOVI

Function:
Format:
Example:
Explanation:
Moves to a point specified by a point number (Moves to an absolute
position relative to the origin point).
MOVA
<point number>, <maximum speed>
MOVA
51, 80
Moves to P51 at speed 80.
This command moves the robot to a position on the absolute coordinates
whose origin position is defined as 0.
The robot starts moving when all axes enter the positioning-completed
pulse range, and stops when all axes reach the OUT valid position.
(1) Point number
The point number is a number designated to each point from 0 to
999, a total of 1000 points, and used to create point date in PNT
(point) mode. When a character "P" is entered here for special use, a
point variable defined by the "P" statement is set as the point number.
(See "8-4-12 P".)
(2) Maximum speed
The maximum speed can be set to any level between 1 and 100. If
the execution speed in OPRT mode is 100, then 100 will be equal to
2000 mm/sec. (when PRM44=2000).
Moves a distance specified by a point number from the current position.
MOVI
<point number>, <maximum speed>
MOVI
10, 80
Moves an amount equal to point data P10 from the current position at
speed 80.
This command moves the robot on the relative coordinates with the cur-
rent position viewed as 0.
The robot starts moving when all axes enter the positioning-completed
pulse range, and stops when all axes reach the OUT valid position.
(1) Point number
The point number is a number designated to each point from 0 to
999, a total of 1000 points, and used to create point date in PNT
(point) mode. When a character "P" is entered here for special use, a
point variable defined by the "P" statement is set as the point number.
(See "8-4-12 P".)
(2) Maximum speed
The maximum speed can be set to any level between 1 and 100. If
the execution speed in OPRT mode is 100, then 100 will be equal to
2000 mm/sec. (when PRM44=2000).