Siemens SINAMICS S120 Combi Equipment Manual page 259

Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

Comparison of MOTION-CONNECT power cables
MOTION-CONNECT 500 power cables are mainly suitable for permanent routing. MOTION-
CONNECT 800 power cables fulfill all of the high mechanical requirements for use in tow
chains. They are resistant to cutting oils.
Table 12- 10 Comparison of the MOTION-CONNECT 500 and MOTION-CONNECT 800 power cables
Power cable
Approvals
VDE
1)
cUL or UL/CSA
UL-CSA File No.
2)
RoHS conformance
Rated voltage V
/V
0
in accordance with EN 50395
Supply cores
Signal cores
Test voltage, rms
Supply cores
Signal cores
Operating temperature at the surface
Permanently installed
Moveable
Tensile load, max.
Permanently installed
Moveable
Smallest bending radius
Permanently installed
Moveable
Torsional stress
Bending operations
Max. traversing speed
Max. acceleration
insulation material
Oil resistance
Protective jacket
Flame retardant
1) The registration number is printed on the cable jacket.
2) The file number is printed on the cable jacket.
SINAMICS S120 Combi
Manual, Edition 05.2010, 6SL3097-4AV00-0BP0
MOTION-CONNECT 500
Yes
UL758-CSA-C22.2-N.210.2-M90
Yes
Yes
600 V / 1000 V
24 V (EN) 1000 V (UL/CSA)
4 kV
2 kV
-20 to +80°C
0 to 60°C
50 N/mm
2
20 N/mm
2
5 x D
max
approx. 20 x D
max
30°/m absolute
100000
30 m/min
2 m/s
2
CFC/silicone-free
EN 60811-2-1
(mineral oil only)
PVC
EN 60332-1-1 to 1-3
Cabinet design and EMC
12.7 Cable shielding and routing
MOTION-CONNECT 800
Yes
UL758-CSA-C22.2-N.210.2-M90
Yes
Yes
600 V / 1000 V
24 V (EN) 1000 V (UL/CSA)
4 kV
2 kV
-20 to +80°C
-20 to +60°C
50 N/mm
2
20 N/mm
2
6 x D
max
approx. 12 x D
max
30°/m absolute
10 million
from 10 mm
: 3 million
2
180 m/min
from 10 mm
: 100 m/min
2
5 m/s
(5 m); 10 m/s
(2.5 m)
2
2
CFC/halogen/silicone-free
IEC 60754-1 / DIN VDE 0472-815
EN 60811-2-1
PUR, HD22.10 S2
(VDE 0282, Part 10)
EN 60332-1-1 to 1-3
259