Table 1 Chassis structure
Section
(1) LPU slots
(2) MPU slots
(3) Power
supply slots
(4) Fan tray slot
(5) Switching
fabric module
slots
NOTE:
x
The installation procedures for LPUs, MPUs, and switching fabric modules are similar. They are
collectively called cards in this installation guide unless otherwise specified.
x
For more information about the cards, power supplies, and fan trays available for the A10500 switches,
see the chapter "Appendix B FRUs and compatibility matrixes."

Switch and FRU aliases

The following tables list the aliases of the A10500 switches and FRUs in this installation guide:
x
Table 2
x
Table 3
x
Table 4
x
Table 5
x
Table 6
x
Table 7
x
Table 8
Description
Both LPUs and LPU slots are purple
edged for easy identification.
Both MPUs and MPU slots are pink
edged for easy identification.
x
The A10504 has four power
supply slots.
x
The A10508 and the A10508-V
have six power supply slots.
Location of the fan tray slot:
x
A10504 and A10508—Left rear
of the chassis
x
A10508-V—Upper rear of the
chassis
Both switching fabric modules and
switching fabric module slots have
silver gray edges.
for A10500 switch chassis
for MPUs
for switching fabric
for LPUs
for power supplies
for mounting accessories
for fan assemblies
Remarks
N/A
You must install at least one MPU.
N/A
Every A10500 switch comes with one fan tray.
You do not need to order fan trays.
You must install at least one switching fabric
module.
You can install up to four switching modules, and
one of them must be installed in one of the two
lowest numbered switching fabric module slots.
x
For the A10504, you must at least install one
switching fabric module in slot 6 or slot 7.
x
For the A10508 or A10508-V, you must at least
install one switching fabric module in slot 10 or
slot 1 1.