4.4.2 Reading SD Dictionary by General-purpose Communication Command
Reading dictionary (Learning data only)
Send
% D R ? ? BCC CR
?? = 00 - 99 (Dictionary No.)
Receive
% D R $ BCC CR
Error (Error 1 signal = ON)
% D R
Reading all dictionary data
Send
% A D ? ? BCC CR
?? = 00 - 99 (Dictionary No.)
Receive
% A D $ BCC CR
Error (Error signal = ON)
% A D
4.4.3 Reading SD Dictionary by PLC Communication Command
Reading dictionary (Learning data only)
Command
CIR
CIR+1
CIR+2
CIR+3,CIR+4
Reading all dictionary data
Command
CIR
CIR+1
CIR+2
CIR+3,CIR+4
!
Error code (3-digit)
!
Error code (3-digit)
0600 h
0242h
4
Dictionary No.
0600 h
0252h
4
Dictionary No.
BCC
CR
BCC
CR
Response result
COR
Result output completion = 1
COR+1
COR+2
Response result
COR
Result output completion = 1
COR+1
COR+2
Normal end=0
or Error code
0
Normal end=0
or Error code
0
105