External Page With Biou Interface - Toshiba Strara CTX Series Installation And Maintenance Manual

Digital business telephone systems
Table of Contents

Advertisement

Peripheral Installation

External Page with BIOU Interface

Up to two BIOU interfaces can be installed for connecting external page equipment. Each BIOU can
provide up to four unique page zones for a total of eight page zones maximum per system. The BIOU
interfaces can be installed in the main cabinets and/or any remote cabinet. Each BIOU provides a
600ohm, non-amplified page output and an 8 ohm, 3-watt amplified page output. Only one type of
page output, amplified or non-amplified, can selected per BIOU in a given installation. The BIOU also
provides a control relay which can be used to mute external BGM when the external page circuit is
active (see
Figures 8-8~8-12
Page, BGM
or Night Ringing
switched in by
System Processor
System
Back Plane
Figure 8-9
Single Zone Page Options
A separate external BGM source can be connected to a building's external Page speakers using the
BIOU interface. This enables the BGM sent over the external page speakers to be different from the
BGM sent to telephone speakers (see
Night Ring
and Page
from KSU
Backplane
BGM Mute Relay
Figure 8-10
Separate BGM Over External Page
8-10
for connection diagrams).
BIOU (1 or 2)
600
Transformer
SPO
SW600 (Select SPO or SP1)
SP1
SP
Figures
BIOU (1 on 2)
1
600Ω
B
2
M
Level Control
3 Watt Amplifier
8-10) for separate BGM over external Page connections).
MDF
SPT (38)
BK-GN
SPR (13)
GN-BK
66 Block Wiring
Jacketed
Twisted Pair
CW1308 0.5
HESB
SPTO 38, BK-GN
or
External
SPRO 13, GN-BK
Amplifier
and Speaker
HESB
SPT1 50, V-S
or
External
SPR1 25, S-V
Speaker
(8ohm minimum)
5605
External
Paging Amp
Mute 2
Input 2
BGM
Music
Source
5601
Strata CTX I&M September 2002

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strara ctx100Strara ctx670

Table of Contents