Page 2
électrique, d’incendie ou de blessure n’effectuer que les réparations indiquées dans le mode d’emploi à moins d’être qualifié pour en effectuer d’autres. Pour toute réparation faire appel à une personne compétente uniquement. BDX-N1000 Serial No. 10001 and Higher BDKP-N1001 Serial No.
Page 3
Attention-when the product is installed in Rack: (For BDKP-N1002) (For BDX-N1000) Laser Diode Properties Material : InGaAsP 1. Prevention against overloading of branch circuit Wave length : 1300 nm When this product is installed in a rack and is Emission duration...
Manual Structure Purpose of this manual This manual is the installation manual of the BDX-N1000 Network Interface Unit and the BDKP-N1001/N1002/N1003/N1004 Network Adapter Boards. This manual is intended for use by trained system and service engineers, and describes information regarding installation.
1 Power cord, 250 V 10 A (2.4 m) : ! 1-551-631-15 the BDX-N1000 is installed. 2 Plug holder (Brown) : 3-613-640-01 The rear side of the BDX-N1000 should be at least 20 cm (8 inches) away from walls for ventilation and AC inlet maintenance.
. Washer for rack mounting : 4 pcs. (Sony part number: 2-297-913-01) *1 : The BDX-N1000 comes with the eight screws. The two screws of them are spare. Be sure to use the RMM-30 rack mount rail. If a rack mount rail other than the RMM-30 is used, the BDX-N1000 may be dropped by insufficient strength of the rack mount rail.
Page 12
1-4. Rack Mounting 4. Attach the inner rails to the BDX-N1000 using the six 6. Attach the front brackets to the inside of the rack screws (B 4x8) supplied with the BDX-N1000. temporarily using the two screws (PWH 4x10) and the two plate nut supplied with RMM-30.
Page 13
BDX-N1000 about 20 cm (8 inches), and fasten the screws of the front brackets to the rack. 10. After installing the BDX-N1000 in the rack, secure the unit to the rack by the prepared four screws (RK 5x16) and four washers.
1-5. Matching Connectors and Cables 1-5. Matching Connectors and Cables When connecting cables to various connectors on the rear panel at the time of installing or servicing, connect the following connectors/cables or their equivalents. Connector on the BDX-N1000 Matching Connector/Cable Panel Indication Connector/Cable Sony Part No.
S/N : 10001 to 10843 CLOSE : Write-protection function OFF . Do not change settings of the switches that are specified OPEN : Write-protection function ON as “Factory use only” and “Unassigned”. Factory setting : CLOSE (lower position) 1-8 (E) BDX-N1000...
S1-3 : ON S1-4 : ON S1103 (G-5) : Factory use only Factory setting : 0 S1600 (A-1) : Reset switch Do not press this switch in normal operation. 1) : Serial No. 10001 to 10843 only. 1-9 (E) BDX-N1000...
ATM I/O connector on the rear panel. ON : When the length of the cable is 68 m or more OFF : When the length of the cable is less than 68 m Factory setting : OFF 1-10 (E) BDX-N1000...
Factory setting : ON S100-7 : Transmission mute select switch ON : To mute (not to send data) OFF : Not to mute (to send data) Factory setting : OFF S100-8 : Unassigned Factory setting : ON 1-11 (E) BDX-N1000...
CCM-36/36A board Support 2-2-1. Installation Procedure 1. Turn off the power of the BDX-N1000 and remove the power plug from the outlet. 2. Remove the six screws (B 4x6), and remove the top Support panel.
9. Stick the tape on the portion shown in the figure from Preparation inside of the unit. 1. Connect the equipment. Rear panel (inside view) 2. Turn on the power of the BDX-N1000 and warm up the unit about 10 minutes. Tape SC connector Checking procedures 1.
Page 24
. MPEG encoder unit, BDX-E1000 on the IF-694 board as shown below. . MPEG decoder unit, BDX-D1000 . Video monitor (Sony BVM series or equivalent) Set the switches in the state of power-off, and after settings are changed, turn the power-on.
2-3-1. Installation Procedure 5. Align the four screw holes of the board with the four supports. 1. Turn off the power of the BDX-N1000 and remove the power plug from the outlet. BNC connectors 2. Remove the six screws (B 4x6), and remove the top panel.
B 3x6 Rear panel Preparation 1. Connect the equipment. 2. Turn on the power of the BDX-N1000 and warm up the unit about 10 minutes. Checking procedures 1. Connect CH2 of an oscilloscope to TP100 (B-1) on the CCM-40/40A board.
Page 27
. MPEG encoder unit, BDX-E1000 on the IF-694 board as shown below. . MPEG decoder unit, BDX-D1000 . Video monitor (Sony BVM series or equivalent) Set the switches in the state of power-off, and after settings are changed, turn the power-on.
Clean the air filter periodically because it apt to catch dust. Filter 1. Air filter at the inside of the front panel If the BDX-N1000 is kept on operating with too dusty of the filter, the temperature inside the unit getting rise. This may cause a fire.
D301 (J-2, G-2) (green) : Ethernet status indicator Lights up when data is transmitted to the Ethernet port. It is recommended to replace the filter every five years as a D500 (D-5) (green) : Factory use only guide. . Filter (B): 3-622-576-01 3-2 (E) BDX-N1000...
Page 31
Lights up when an error occurs in the PCR dejitter process- D6100 (A-3, A-4) (green) : TS output status indicator ing (IC1100). Lights up when the clock for the PCR dejitter is synchro- nized in the clock of network. D1400 (E-6, D-6) (green) : Factory use only 3-3 (E) BDX-N1000...
5) Serial No. 10001 to 10843 only . LOS (Loss of Signal) . LOF (Loss of Frame) . LOC (Loss of Cell Delineation) D2 (B-1) (red) : Optical input alarm Lights up when optical input signal does not exist. 3-4 (E) BDX-N1000...
CCM-40A Board (BDKP-N1004) D101 D100 (Side A/Component side) The number shown in parenthesis ( ) indicates addresses on the board. D100 (D-3) (red) : Unassigned D101 (B-2) (red) : Input alarm Lights up when input signal does not exist. 3-5 (E) BDX-N1000...
Page 35
The material contained in this manual consists of information that is the property of Sony Corporation and is intended solely for use by the purchasers of the equipment described in this manual. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any...