Test Equipment List

DMM Calibrator : 1 set
Decade Resistor : 1 set
DC Power Supply or 9V Battery
n

Calibration Procedure

1. Power On Test

Set DM-311 to any mode by using Rotary S/W.
Check LCD display is turned on.

2. LCD Display Test

Check LCD Display to each range by selecting range with Rotary S/W. Below chart shows correct display
Function
DC VOLTAGE
AC VOLTAGE
DC CURRENT
AC CURRENT
RESISTANCE
BAT
DIODE &
CONTINUITY
3. Low Battery Warning Display Test
Check a message, "BATT" on LCD display when Power supply or Battery Voltage goes under 6.4V.