Servo control

5.11 Increased stall power at the voltage limit

5.11
Increased stall power at the voltage limit
Function description
As a result of a new voltage management, in operation, the spindle power can be briefly
increased to the stall power limit. The stall power limit is the range in which the motor power is
limited as a result of the maximum converter output voltage. This stall power range is normally
marked in the motor data sheets (voltage limit characteristic) and depends on the motor type
(induction/synchronous motor) and the DC-link voltage magnitude (see figures shown further
below).
Constraint
An increased stall power is not possible for motors that have sufficient clearance to the voltage
limiting characteristic over the complete speed range.
Note
As a result of the field-orientated control, for operation at the voltage limit there is no danger of
the motor stalling. This applies regardless of whether the operation takes place at the voltage
limit with or without activated increased stall power.
Activation/deactivation effects
Activating and deactivating the increased stall power as the following effect:
● Increased stall power; p1402.6 = 1
– The motor stall torque correction factor can be set via p0388.
– The stall power can be set higher since it will be reduced by a controller as required.
● Normal stall power; p1402.6 = 0
– The motor stall torque correction factor can be set via p0326.
– Stall power must be very precisely set.