Turning On The Mw 800; Turning Off The Mw 800; Replacing Power Cable Fuse (Vehicle Power) - Motorola MW 800 Series Vehicle Installation Manual

Hide thumbs Also See for MW 800 Series:
Table of Contents

Advertisement

2. Turn OFF the MW 800 via the OS. Note that in order to turn ON the MW 800, the
ignition key should be turned to OFF position, and switched back to ON.

Turning On the MW 800

Before powering ON the MW 800:
• Verify proper display to CPU cable connection on both sides.
• Verify keyboard connection to the display.
• Verify that the vehicle power system can supply at least 15 Amps.
• Check that the power cables are plugged into the power connectors of the CPU box and the
display.
Note
• Switch ON the main power switch (MAIN SWITCH) on the back panel of the CPU box.
If the MW 800 is connected through the ignition switch, insert the car key into the ignition
switch and rotate it to ACC position, or start the engine, before powering ON.
To power the workstation, press the Power button on the front panel of the CPU box, or press
the Workstation Power button on the display.

Turning Off the MW 800

To turn Off the workstation, press the CPU box or display Power button momentarily. The
workstation displays the Windows shut-down dialog box. Remember to save important
information before turning OFF the MW 800.
The MW 800 automatically turns OFF as a result of the following events:
• Extreme temperatures
• Discharged vehicle battery
• Pressing the Power button on the CPU box or display for more than six seconds
In critical conditions or during maintenance, the workstation may be powered OFF by
turning the main power switch on the CPU box back panel.

Replacing Power Cable Fuse (Vehicle Power)

Remove the fuse (15A) from the fuse holder located on the Motorola DC cable and replace it
with a new one of the same type and value (part no. 6580283E06).
The main power switch on the CPU box back panel (MAIN SWITCH) must
be in OFF position before connecting to power supply source.
Turning OFF the main power switch or disconnecting the power cable
!
when the MW 800 is running may seriously damage your operating
system or your hard disk.
Caution
Installation
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mw 800 f5206Mw 800 f5207Mw 800 f5217

Table of Contents