Service and maintenance
5.2 Replacing the cooling fan
5.2
Replacing the cooling fan
The service life of the cooling fan
The average service life of the cooling fans is 40,000 hours. In practice, however, the service
life may deviate from this value. Especially a dusty environment can occlude the fan.
The fan must be replaced in good time to ensure that the inverter is available.
Cooling fan replacement for FSA ... FSC
Removal
1. Power-down the inverter
2. Disconnect all the cable connectors from
3. Press locking latches (one for FSA, two for
4. Pull the fan module out of the Power
Installation
For re-installation, carry out the above steps in
reverse order.
Note
The fan only fits, if you use the right direction and orientation.
38
the Power Module
FSB and FSC) to release the fan module
module
Fan replacement - example
Power Module PM230, IP20 / Push through
Hardware Installation Manual, 03/2012, A5E03448282B AA