Line/Load Connection - Siemens SINAMICS S120 Equipment Manual

Booksize power sections cold plate
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

4.5.3.2

Line/load connection

Line filters for Smart Line Modules are rated for a voltage range from 380 V 3AC -10% to
480 V 3AC +10% (-15% <1 min) at 47 Hz to 63 Hz.
Table 4-8
Type of connection
Terminals
Line connection (line)
Load connection (load)
Line filters for Smart Line Modules
5 kW
10 kW
16 kW
36 kW
1) for ring cable lugs to DIN 46234
Equipment Manual Booksize Cold-Plate Power Sections
Manual, (GH4), Edition 06.2005, 6SL3097-2AJ00-0BP2
Designations
L1, L2, L3, PE
L1´, L2´, L3´, PE
Screw terminal: 10 mm
3-pin/1.5 Nm (see Screw Terminals)
2
Ground stud: M6/4.8 Nm
1)
Screw terminal: 10 mm
3-pin/1.5 Nm (see Screw Terminals)
2
Ground stud: M6/4.8 Nm
1)
Screw terminal: 10 mm
3-pin/1.5 Nm (see Screw Terminals)
2
Ground stud: M6/3 Nm
1)
Screw terminal: 35 mm
2
Ground stud: : M6/3 Nm
1)
Line Connection
4.5 Line filters for Smart Line Modules
4-17