Bosch Rexroth VM350 Manual
Hide thumbs Also See for Rexroth VM350:

Advertisement

VM350
Reset
Reset
INT
EXIT
Reset
XDN2
X1S2
LTU350/1
LTU350/1
VM350
Reset
Reset
Reset
LT353
LT353
LT353
3 609 929 B32/
2008-09

Advertisement

Table of Contents
loading

Summary of Contents for Bosch Rexroth VM350

  • Page 1 VM350 3 609 929 B32/ 2008-09 Reset Reset EXIT Reset XDN2 Reset Reset Reset X1S2 LT353 LT353 LT353 LTU350/1 LTU350/1 VM350...
  • Page 2: Table Of Contents

    Maintenance and repair ....35 specifications, and other information set forth in it, are the exclusive property of Bosch Decommissioning ....35 Rexroth AG.
  • Page 3: About This Document

    22/112 Bosch Rexroth AG VM350 | 3 609 929 B32/2008-09 About this document • Always include the operating instructions when you pass the VM350 power supply This manual contains important information module on to third parties. on the safe and appropriate assembly,...
  • Page 4 3 609 929 B32/2008-09 | VM350 Bosch Rexroth AG 23/112 out by qualified technical personnel or an This warning symbol cautions instructed person under the direction and against dangers to your health supervision of qualified personnel. caused by electrical voltage or Qualified personnel are those who can currents.
  • Page 5: Delivery Contents

    24/112 Bosch Rexroth AG VM350 | 3 609 929 B32/2008-09 Check the product for visible defects, for During cleaning example damage to the circuit board, Cover all openings with the appropriate components, housing, and plug connectors protective equipment in order to prevent or missing screws.
  • Page 6: Product Description

    3 609 929 B32/2008-09 | VM350 Bosch Rexroth AG 25/112 Product description Performance description Device description The VM350 power supply module supplies the intermediate circuit voltage or intermediate circuit power for the power packs of the 350 tightening system and provides the power supply to all the cards within the 350 tightening system.
  • Page 7 26/112 Bosch Rexroth AG VM350 | 3 609 929 B32/2008-09 Displays and operating elements LED Ready for operation Temperature and voltage errors can only be LED Mains voltage error reset by switching the whole system off and LED Intermediate circuit voltage error on again, or by pressing the Reset button on the front panel.
  • Page 8 3 609 929 B32/2008-09 | VM350 Bosch Rexroth AG 27/112 X1S1 user interface for external 24 V XDN2 user interface power supply The XDN2 interface is located on the front The X1S2 interface enables the external 24 V panel. This serves to: power supply.
  • Page 9 28/112 Bosch Rexroth AG VM350 | 3 609 929 B32/2008-09 CAUTION NOTE! Risk of damage to persons The maximum torque at the bolted and property! connections of the terminals at XDN2 must not exceed 0.3 Nm. The voltage circuits on terminal...
  • Page 10 3 609 929 B32/2008-09 | VM350 Bosch Rexroth AG 29/112 CAUTION CAUTION Risk of damage to persons Risk of damage to persons and property! and property! The user is obliged to maintain Dangerous shock currents due to the system-specific require-...
  • Page 11 30/112 Bosch Rexroth AG VM350 | 3 609 929 B32/2008-09 Examples of emergency OFF in the 350 tightening system (in BT356 and SB356) Stationary tightening spindles (shutdown via VM350): Case 1 Fall 1 Bridge Brücke Direct use of the emergency...
  • Page 12 3 609 929 B32/2008-09 | VM350 Bosch Rexroth AG 31/112 Stationary tightening spindles (shutdown via mains lead) An additional external 24 V power pack can be connected via the X1S2 interface. If the mains power supply is switched off, this supplies the electronics in the 350 tightening system (external field buses such as e.g.
  • Page 13 32/112 Bosch Rexroth AG VM350 | 3 609 929 B32/2008-09 Boundary conditions: Case B: Use of an emergency OFF switch device, e.g. • 24 V supply from an internal power pack PNOZ: • emergency OFF operating device • The cut-out of the emergency OFF circuit according to ISO 60947-5-1.
  • Page 14 3 609 929 B32/2008-09 | VM350 Bosch Rexroth AG 33/112 Hand-held tightening spindles: CW / CCW 1 mm Fig. 6: Switch S1: We recommend the use of a position switch, The PLC or the switch on the hand-held e.g. Telemecanique ZCK-M8. Connect the nutrunner sends a Cw/Ccw signal.
  • Page 15: Transport And Storage

    34/112 Bosch Rexroth AG VM350 | 3 609 929 B32/2008-09 Transport and storage Assembling VM350 power supply module For storing and transporting the product, always observe the ambient conditions CAUTION specified in the technical data (see Risk of damage to persons “Technical data”...
  • Page 16: Commissioning

    3 609 929 B32/2008-09 | VM350 Bosch Rexroth AG 35/112 Operation 1. Switch off the power supply for the BT356 card rack or SB35x system box Operation is not necessary while the system is and allow for a discharging time of running.
  • Page 17: Disassembly And Replacement

    Therefore, dispose of the device in for XDN2: 0.4 x 2.5 mm accordance with the currently applicable regulations in your country. Disassembling You can also send the device to Bosch Rexroth for disposal. CAUTION Remove the VM350 power supply module while live.
  • Page 18: Technical Data

    3 609 929 B32/2008-09 | VM350 Bosch Rexroth AG 37/112 Technical data Table 4 General data VM350 Order number 0 608 750 110 Input Input voltage 200 - 265 V, single or three-phase, 50 - 60 Hz Input current Depending on the voltage and type of connection, e.g.
  • Page 19: Service And Sales

    Bosch Rexroth AG VM350 | 3 609 929 B32/2008-09 Service and sales Service Sales Bosch Rexroth AG Electric Drives and We are always the right partner when it Controls Schraub- und Einpress-Systeme comes to system know-how. Fornsbacher Str. 92 D-71540 Murrhardt...

Table of Contents