Preparing The Operating Pc Or Service Notebook - Siemens 7XV5655-0BB00 Manual

Modem for transmission of serial data or protocols from devices with an rs232, rs485 or fo interface via ethernet
Hide thumbs Also See for 7XV5655-0BB00:
Table of Contents

Advertisement

Manual 7XV5655-0BB00

Preparing the Operating PC or Service Notebook

Before commissioning the Serial Modem, the following precautions must be taken on
the on the operating PC or service Notebook.
This requires the following operating systems
Windows® XP Prof. 32-Bit SP3
Windows® 7 Prof. 32-Bit SP1
Windows® 7 Prof. 64-Bit SP1
Windows® Server 2008 R2 / 64-Bit
These Windows Operating Systems were used to test the installation as well as
the full scope of functionalities of the device.
Installation of the Modem Driver
To operate the Serial Modem in a WINDOWS
link, the modem driver must first be installed in the WINDOWS® Control Panel.
The modem-driver „ipEtherModem_Setup" for the serial modem contains two
files "ipEtherModem.inf" and "ipethermodem.cat".
Installing the Configuration Software V15
For the installation of the configuration tool corresponding set-up files are
available for the various WINDOWS
"ipEther.config.Setup_x86.exe" for Windows
"ipEther.config.Setup_x64.exe" for Windows
There are two ways of configuring the Serial Modem using the configuration tool
via the Ethernet interface.
1. The modem is connected directly to the operating PC/Notebook using a
cross-over patch cable. After the configuration tool has been started, the
connected Serial Modem is automatically located and can be configured.
2. The Serial Modem is connected with a patch cable to a switch in an
existing network, to which the operating PC/Notebook is connected as
well. After the configuration tool has been started, all connected Serial
Modems are located automatically and can be configured. To configure
Serial Modems that are located in another network segment (e.g. behind a
router), they must be searched for in the network by manually entering the
IP address. The IP-addresses of these modems cannot be changed.
Configuring the Ethernet Interface of the Operating PC
For the operating PC to be able to communicate with the Serial Modem, the
Ethernet interface of the operating PC/Notebook must be configured accordingly.
C53000-G1176-C175-3
®
application requiring a dial-up
®
-Operating Systems.
®
XP SP3 and 7 SP1 32-Bit
®
7 SP1 64-Bit and Server 2008 R2
Page 20 of 79
SIEMENS AG

Advertisement

Table of Contents
loading

Table of Contents