default values shown below:
Attribute
Initiator ID
Speed
Auto termination
The A5149A HBA with part number A5149-60001 also has a problem in
that the SCSI cable must be disconnected when performing an online
replacement. See "What to Do" below for details.
If you have an HP 9000 N-Class, L-Class, or Superdome system running
HP-UX 11i and want to do OLA/R of the SCSI HBAs A4800A, A5149A,
A5150A, and A5159A, you need to consider these restrictions.
The things you need to do for online addition and online replacement are
described below.
For Online Addition: You can add an HBA online only if the values of
the initiator ID and speed attributes are usable in your SCSI
configuration. The initiator ID and speed attributes will be set to the
current PDC values (if any) or be defaulted to the new HBA's values
(default values are in the table above). The auto termination attribute
always uses the HBA's default value.
For Online Replacement: The online replacement operation preserves
the initiator ID and speed settings across the replacement. The auto
termination setting in PDC (applicable to the A5150A with part number
A5150-60101) is not preserved across the replacement. For A5149A,
A5150A with part number A5150-60001, and A5159A, remember to set
the auto termination jumpers in the same position as they were on the
replaced HBA.
For online replacement of A5149A with part number A5149-60001,
follow these steps:
Step 1. From SAM, select:
Appendix B
7
Fast for A4800A and A5159A
Ultra2 for A5149A and A5150A
Not applicable for A4800A
Enabled for A5150A (part number A5150-60101)
Controlled by jumper settings for A5149A, A5150A
(part number A5150-60001), and A5159A
Areas -> Peripheral Devices -> Cards