Installing Transceiver Unit - Siemens SIMATIC HMI Series Operating Instructions Manual

Industrial flat panels v2
Hide thumbs Also See for SIMATIC HMI Series:
Table of Contents

Advertisement

Installing and connecting the device

3.4 Installing Transceiver Unit

3.4
Installing Transceiver Unit
Note
Important notes for installation
• The device is approved for operation in closed rooms only.
• For installation in a cabinet, read the manual "Installing control systems interference-proof
(https://support.industry.siemens.com/cs/ww/en/view/59193566)" as well as the relevant
DIN/VDE provisions and the applicable country-specific regulations.
Requirements
● The mounting rail is fastened to the side or rear of the Transceiver Unit according to the
desired mounting position.
Mounting onto standard rail
The following procedure describes an example of mounting a Transceiver Unit with a
mounting rail attached at the side on a standard mounting rail. The mounting of a
Transceiver Unit with a mounting rail attached at the rear is carried out in the same way.
Proceed as follows:
1. Place the device with the mounting rail clip from below onto the standard mounting rail.
Make sure that the unit does not tilt.
2. Push the device upward.
3. Push the device towards the standard mounting rail until the standard mounting rail clip
engages completely at the top.
56
Operating Instructions, 08/2019, A5E46641410-AA
IFP V2, IFP V2 PRO

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic ifp v2Simatic ifp v2 pro

Table of Contents