14.3 Lap timing

14.3.1 Time based retrigger protection
14.3.2 Distance based retrigger protection
Bosch Motorsport
[###03] indicates: 'always use 3 digits with leading zeros'.
There are different possibilities to adjust the lap trigger to the timing situation.
The detection time defines the minimum time the input signal changes its state. E.g. a low
active signal needs to be below the threshold for min. 15 ms to release the trigger.
Channels for display
To display lap times use the following channels:
Channel
Laptrigger_lapctr_dls
Laptrigger_laptime_dls
Laptrigger_laptime_best_dls
Laptrigger_laptimeold_dls
Laptrigger_laptimeseg_dls
Laptrigger_lapctr_dls
Trigger is locked for 5 s after main trigger was received.
To deactivate time based retrigger protection, set 'Retrigger lock time' to 0 ms.
Define settings for lap timing
(main trigger).
Define settings for sub trigger.
Not applicable with a GPS lap trigger.
5000ms
Main Trigger
Trigger is locked until configured min distance (i.e. 80 % → 3200 m) of track distance (i.e.
4000 m) has been covered. To deactivate distance based retrigger protection, set min dis-
tance to 0 %.
Data Logger C 70 Manual
Function
Number of completed laps
Running laptime
Laptime of best lap
Laptime of last lap completed
Segment time of last segment
Number of completed laps
Lap Trigger | 14