Connect The Power - HP TippingPoint Series Hardware Installation And Safety Manual

Table of Contents

Advertisement

Special Wiring Considerations
The TippingPoint1 10 and 330 include integrated Zero-Power High Availability (ZPHA) relays. The ZPHA
relays provide a network bypass for Ethernet traffic in the event that the IPS loses power.
When you install and configure a device with integrated ZPHA, you should first connect the network cables
with the device powered off and ensure that link is established and traffic passes successfully. If so,
installation can proceed normally.
If the device does not pass traffic while powered off, ensure that you have the appropriate cable for your
network. In many cases, replacing a straight-through cable with a cross-over cable will resolve link issues.
In addition, ensure that all IPS interfaces and connected switches have the same linespeed and duplex
settings.

Connect the Power

The TippingPoint 1 10/330 includes a power cable. Follow these steps to connect power to the device.
1.
Plug one end of the provided power cable into the power input at the back of the device.
2.
Plug the other end into an AC outlet, power strip, or UPS. The power should meet the following
requirements:
• Voltage: 1 10-240 VAC
• Current
• At 1 10 V: 6A
• At 240 V: 3A
• Frequency: 50-60 Hz
After you plug in the unit, push the power switch on the rear of the device into the On position. The Power
LED on the front panel will turn green to show that power is present.
Using the Power Switch
Use the following procedure to power down the TippingPoint 1 10/330 while power is connected:
1.
In the CLI, issue the
When the command is successfully executed, the Status LED will turn off.
2.
Push the power switch on the rear of the device into the Off position.
Push the switch into the On position to turn the device back on.
If AC power is lost while the power switch is in the On position, the device will start automatically when AC
power is re-connected.
CAUTION:
Do not turn off the power using the switch without first shutting down the unit with a clean
shutdown.
Using the Reset Button
Use the Reset button to perform a graceful shutdown or to restart the TippingPoint 1 10/330 in the event that
the unit becomes unresponsive to LSM and CLI commands.
To perform a graceful shutdown with the Reset button, press and hold the Reset button for 2 seconds. After
2 seconds, the unit beeps and begins the shutdown sequence. The status LED turns yellow, the unit goes
into bypass mode, and the segment active LEDs are extinguished. When the graceful shutdown is
complete, the status LED on the front is extinguished. You may then disconnect the power or use the power
switch to complete the system shutdown.
command.
SHUTDOWN
TippingPoint 10/110/330 Hardware Installation and Safety Guide
27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tippingpoint 110Tippingpoint 10Tippingpoint 330

Table of Contents