Installation Options; Technical Specifications; Ups Bridging Time/Charging Time - Siemens HiPath 3000 Series Service Documentation

Table of Contents

Advertisement

exup.fm
Expanding and Upgrading HiPath 3000
HiPath 3000Expanding
9.1.3.3

Installation Options

Use the power cable to ground the Powerbox PB3000. Fixed, separate grounding is
>
not required.
The Powerbox PB3000 can be installed as follows:
in a 19-inch cabinet (see Section 9.1.3.8).
mounted on a wall (see Section 9.1.3.7)
on a desktop using four adhesive mounting feet
For information on the assembly kit for wall attachment or desktop installation, see Section
9.1.3.2.
9.1.3.4

Technical Specifications

Table 9-2
Technical Specifications for PB3000
Powerbox PB3000 / Components
Powerbox PB3000
- including batteries and LUNA2 power supply
Battery compartment - including 4 batteries
Single battery (12 V / 7 Ah)
LUNA2 power supply
9.1.3.5

UPS bridging time/charging time

USP bridging times and charging times when using the PB3000 with 48 V / 7 Ah batteries and
LUNA2 power supply (at maximal continuous current less than 2A, for all loads):
Example PB3000 - HiPath 3300/3500
UPS bridging time: >1 h 30 min
Battery charging time: ~ 2 h
Example PB3000 - HiPath 3800
UPS bridging time: > 30 min
9-14
Nur für den internen Gebrauch
Technical specifications
Weight when empty: 7.0 kg
Total weight: 21.0 kg (13.22
lb.)
Weight: 12.0 kg
Weight: 2.65 kg
Weight: 2.0 kg
For further information on
LUNA2 power supply, see
Section 3.2.12
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation