Optional Arguments:
DEFAULT=<default> Read / Write. Set / display default mode of Com2 on boot.
CONSOLE
DATA
INT_LOOP
EXT_LOOP
SURVEY
SNIFFER
MODE=<mode> Read / Write. Set / display mode of COM2.To escape from data
mode, enter three consecutive '+' characters to COM1 with at least 10 mSecs
between them.
CONSOLE
DATA
BSP
INT_LOOP
EXT_LOOP
SURVEY
SNIFFER
BAUD=<baud> Read / Write. Set / display baud rate setting.
1200
2400
4800
9600
19200
38400
57600
115200
FORMAT=<format> Read / Write. Set / display characters, parity, and stop bits
setting of the COM port. '8N1' format.
7N1
7N2
7O1
7O2
7E1
05-XXXXA01 Version 3 Draft
Com2 defaults to Command-line mode.
Com2 defaults to BSP data mode
Com2 defaults to Internal Loopback mode. <Distributor access
level>
Com2 defaults to External Loopback mode <Distributor access
level>
Com2 defaults to Survey-BSP mode
Com2 defaults to Sniffer-BSP mode (Repeater)
Com2 in Command-line mode
Com2 defaults to Basic Serial Protocol mode
Com2 in BSP data mode
Com2 in Internal Loopback mode.
Com2 in External Loopback mode
Com2 in Survey-BSP mode
Com2 in Sniffer-BSP mode (Repeater)
1200 bps
2400 bps
4800 bps
9600 bps
19200 bps
38400 bps
57600 bps
115200 bps
7 char bits, no parity, 1 stop bit
7 char bits, no parity, 2 stop bits
7 char bits, odd parity, 1 stop bit
7 char bits, odd parity, 2 stop bits
7 char bits, even parity, 1 stop bit