5-1. Setting Items of the Primary Station

N : SET DESCRIPTION NAME GROUP

Purpose
To register the Description names required for each remote
control unit, set the group of Description names. Up to
eight such source and destination groups can be set.
(Up to 160 names can be registered for one group.)
The top half of the screen is for setting the group and the
bottom half displays the list of Description names.
Setting Procedure
1. Select menu item [N].
2. Move the cursor to the group number by pressing [B].
3. Enter the group number using the numerical keys, and
press [Enter] to set it.
4. Press [F1] to move the cursor to the lower side of
screen.
5. Select a number and press [Enter]. The Description
name will be copied to the space of the lowest number
on the group setting screen.
To erase the Description names on the group setting
screen, move the cursor to the number and press [BS],
[DEL] or [Ctrl] _ [P].
DESCRIPTION NAME GROUP
GROUP 1 160 REMAIN
001 .......
003 .......
005 .......
007 .......
009 .......
011 .......
013 .......
015 .......
==================================================================
001=OUT001
OUT001
003=OUT003
OUT003
005=OUT005
OUT005
007=OUT007
OUT007
009=OUT009
OUT009
011=OUT011
OUT011
013=OUT013
OUT013
015=OUT015
OUT015
F1:MOVE
F2:JUMP
F3:SOURCE B:Group L:Copy S:Send Ctrl-E:RETURN TO MENU
Example of Setting Screen
m
1. In the remote control unit, the transferred data are all
displayed as input/output numbers.
This is because data is transferred using input/output
numbers instead of input/output names.
2. The group data of the primary and secondary stations'
must be always the same.
If the primary station data is changed after transfer, be
sure to transfer the new data to the secondary station.
5-14
DVS-V6464B V2.10 STATION NUMBER 1
002 .......
004 .......
006 .......
008 .......
010 .......
012 .......
014 ......
016 .......
002=OUT002
OUT002
004=OUT004
OUT004
006=OUT006
OUT006
008=OUT008
OUT008
010=OUT010
OUT010
012=OUT012
OUT012
014=OUT014
OUT014
016=OUT016
OUT016
Operating Function Keys
[F1] : MOVE
(To move the cursor up and down between the
group setting screen and Description name list)
[F2] : JUMP (To move the cursor to the desired element
number)
1. When [F2] is pressed, "Please Input ELE-
MENT NUMBER =" will be displayed.
2. Input the element number to be retrieved.
3. When [Enter] is pressed, the cursor will move
to the desired number.
[F3] : SOURCE (DEST.)
When [F3] is pressed, the Description name list
will be changed from destination to source.
[B] : GROUP
Press [B] to move the cursor to the group number
on the group setting screen.
[L] : COPY (To copy all data in the Description name
group to other groups)
1. When [L] is pressed, the message "Please Input
Original Group Number =" will be displayed
to ask for the group number to be copied.
2. Input the group number to be copied with the
numerical keys and press [Enter]. The data of
all group will be copied to the group setting
screen currently displayed.
[S] : SEND (Transfers all data on the group setting
screen currently displayed to a secondary station)
1. When [S] is pressed, a message "Please Input
Station Number =" will be displayed to ask for
the number of a secondary station to which the
data is to be transferred.
2. Input the number of the secondary station using
the numerical keys and press [Enter].
All data on the group setting screen currently
displayed will be transferred to the secondary
station.
ROUTING SWITCHER SYSTEM (E)