Command Reference

Basic Control Commands

The group of the Basic Control Commands contains 12 commands that enable you to perform the basic operations such as changing the
sound volume, switching the LINE4 SELECTOR of the SRP-X700P and others.
CONTROL S: 43[H] 52[H] 43[H] 53[H] ('CRCS')
This command is used to control an external equipment that is connected to the CONTROL S terminal of the SRP-X700P.
• Packet format
43[H] 52[H] 43[H] 53[H] "parameter" 0D[H]
• Parameter
The parameter consists of the two-byte data in the following order.
byte
Parameter name
1st
CHANNEL
2nd
REMOTE COMMAND
• Channel
Specify the equipment to which you want to send the command.
CHANNEL
LINE 3 INPUT
LINE 4A INPUT
LINE 4B INPUT
LINE 4C INPUT
LINE 4D INPUT
LINE 4E INPUT
LINE 4F INPUT
LINE 4 INPUT
When LINE 4 INPUT is specified, a remote command is sent to the channel that is currently selected by LINE 4 input.
31[H] ( '1' )
32[H] ( '2' )
33[H] ( '3' )
34[H] ( '4' )
35[H] ( '5' )
36[H] ( '6' )
37[H] ( '7' )
38[H] ( '8' )
– 6 –