Ambient Climatic And Mechanical Conditions; Transport And Storage Conditions - Siemens SINUMERIK 840D sl Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

General information and networking
1.2 Application planning
Please note that the final statement on compliance with the standard is given by the respective
label attached to the individual unit.
1.2.2

Ambient climatic and mechanical conditions

1.2.2.1

Transport and storage conditions

The components of the SINUMERIK 840D sl system exceed the requirements according to
EN 61800‑2 with regard to shipping and storage conditions.
The following data applies under the following conditions:
● Long-term storage in the transport and product packaging:
At weather-protected locations that have continuous contact with outside air through
openings.
● Transport in the transport packaging:
– In unventilated containers under conditions not protected from weather effects.
– In the "cold" in accordance with outside air.
– Air transport in the air-conditioned cargo hold.
Table 1-2
Type of condition
Classification
Climate class
Ambient temperature
Biological environmental condi‐
tions
Chemically active environmental
conditions
Maximum permissible tempera‐
ture change
Relative humidity (without conden‐
sation)
Precipitation, rain
Water other than rain
14
Ambient conditions during storage and transport
1)
Direct interaction in air/air:
-40°/+30° C at 95% relative
1 m/s and wet loading surfa‐
Permissible range/class
Transport
EN 60721-3-2
2K4
-40° C ... +70° C
2B1
2)
2C2
3)
humidity
5 to 95%
6 mm/min
2)
ces
4)
Storage
EN 60721-3-1
1K4
-25° C ... +55° C
1B1
2)
1C2
3)
30 k/h
Not permissible
Not permis‐
1 m/s and wet
sible
loading surfaces
5)
Operator panel front: OP 012
Manual, 09/2016, A5E36371591B
4)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ht 8Sinumerik 840de sl

Table of Contents