18
Frames R6i and R7i
Frame R6i and R7i modules have the DC input connection at the top of the module,
while the AC connection is at the bottom. The DC voltage is connected to the input
busbars either through fuses only or through a switch fuse with charging control
circuitry.
The drive control unit (type RDCU) containing the RMIO board is to be installed
separately.
The modules require an external cooling fan that has to be supplied from 230 V or
115 V AC auxiliary voltage. For attaching the fan to the module, mounting plate
64138375 is recommended; alternatively, a combined mounting plate/air baffle can
be constructed.
Module layout
Cabinet layout
See the chapter
Hardware description
1
2
3
Cabinet
construction.
Item
Explanation
1
DC (input) connections
2
Motor (output) connection
3
Cooling fan