Power supply
Degree of protection to EN 60529
Shock, tested in accordance with IEC 68-2-27
Vibration, tested in accordance with IEC 68-2-6
Torsion and bending load
Housing
Transponder attachment
Ambient temperature
Weight, approx.
1)
2)
7.15.5

Dimension drawing

Dimensions in mm
Figure 7-41
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Color
Material
Dimensions (D × pitch × H)
During operation
During transportation and storage
2 hours, 2 m, +20 °C
The values for shock and vibration are maximum values and must not be applied continuously.
Dimensional drawing of MDS D422
Inductive power transmission
(without battery)
IP68
1)
50 g
2)
20 g
2)
not permitted
Black, silver
Plastic PA 6.6 GF; brass nickel plated
M20 × 1 mm × 6 (± 0.2) mm
Screw in (M20 1 mm)
Cement in
-25 °C ... +85 °C
-40 °C ... +100 °C
13 g
Transponder
7.15 MDS D422
6GT2600-4AF00