HP 27115A Installation Manual page 42

Fiber-optic link (hp-fl) device adapter for hp 3000 series 900 computer systems
Table of Contents

Advertisement

Caution
A-2 Cable Installation
When routing the
HP-FL
fiber-optic cable, adhere to the bend radius and stress
limits below. Failure to comply may damage the cable or affect the optical
signals. The "bend radius" and "pull strength" specifications are provided for
both short durations (1 hour) and longer periods. For long periods, bend radius
must be more than 35 mm (1.38 in.) under no tensile force, and tensile force
must not exceed 37 kg (81.5Ib) force with no bend (infinite radius).
Table A-1 shows the characteristics of the cable supplied by Hewlett-Packard.
Table A-2 provides a check list for cable installation.
Table A-1. Fiber-Optic Cable Characteristics
Cable type:
Duplex
Cable length:
S
500m
Markings:
"Transmit" has white sleeve.
Construction:
Graded-index glass fiber
Core/cladding diameter:
100
J1-
m/140
J1-
m
Connectors:
905 type
SMA
Operating temperature:
-20
o
e to 85°e
Storage temperature:
-40
o
e to 85°e
Outer jacket:
Polyurethane (not suitable for air ducts
or plenums)
Exit numerical aperture (NA):
0.3 (for fiber lengths greater than 300 m)
Attenuation:
S
8.0dB/km
Maximum pull strength:
61 kg (@ 25 mm radius
< 1 hr)
37 kg (@
00
radius> 1 hr)
Minimum bend radius:
25mm«
1hr)
35 mm (@ 0 kg stress> 1 hr)
Optical
> 50 MHz • km
Bandwidth • distance product: