Number of data records in a data log
The RECORDS parameter of the "DataLogCreate" instruction specifies the maximum
number of data records that can be stored in a data log.
Time stamp bytes in a data record
● No time stamp = 0 bytes
● Time stamp = 22 bytes
Structure and Use of the CPU Memory
Function Manual, 10/2018, A5E03461664-AC
Bytes
Example 1: MyString String[10]
The maximum character string size is specified with 10 characters.
Text character + automatic filling with spaces = 10 bytes
Quotation marks at the start and end + comma character = 3 bytes
10 + 3 = 13 bytes total
Example 2: Mystring2 String
If no size is specified in square brackets, 254 bytes are assigned by default.
Text character + automatic filling with spaces = 254 bytes
Quotation marks at the start and end + comma character = 3 bytes
254 + 3 = 257 bytes total