D9412G/D7412G
Operation & Installation Guide
EN
Control Panels

Advertisement

Table of Contents
loading

Summary of Contents for Bosch D9412G

  • Page 1 D9412G/D7412G Operation & Installation Guide Control Panels...
  • Page 2 D9412G/D7412G | Operation & Installation Guide | EN | 2 Bosch Security Systems | 10/03 | 43488E...
  • Page 3: Table Of Contents

    D9412G/D7412G | Operation & Installation Guide | Table of Contents EN | 3 Table of Contents Programming the Panel ........20 Install the Point Chart Label ......20 Testing the System ..........20 Introduction ..............7 Power Supply ............. 22 Document Organization ........
  • Page 4 Listings ..............43 System Wiring Diagrams, Issue A ........65 8.4.3 Installation ............... 43 A. 1 D9412G Control Panel, 1 of 3 ......65 8.4.4 Setting the OctoPOPIT Switches ....44 D9412G Control Panel, 2 of 3 ......66 8.4.5 Mounting ..............
  • Page 5 Figure 32: D9412G Faceplate ......... 63 Figure 33: D7412G Faceplate .......... 64 Figure 34: D9412G System Wiring Diagram, 1 of 3 . 65 Figure 35: D9412G System Wiring Diagram, 2 of 3 . 66 Figure 36: D9412G System Wiring Diagram, 3 of 3 . 67 Figure 37: D7412G System Wiring Diagram, 1 of 3 ..
  • Page 6 D9412G/D7412G | Operation & Installation Guide | Table of Contents EN | 6 Notes: Bosch Security Systems | 10/03 | 43488E...
  • Page 7: 1.0 Introduction

    Introduction. Information on the structure of the guide. Lists other literature related to these control panels and describes the FCC rules with which they comply. Overview. Summary of the D9412G/D7412G Control Panels, including operational specifications, standards, and new features. Installation. Instructions for connecting the power terminals, plus the status and battery LEDs.
  • Page 8: Documentation Conventions

    D9412G/D7412G | Operation & Installation Guide | 1.0 Introduction EN | 8 Table 2: Related Documentation Name of Documentation Part Number D1255 Installation Instructions 74-06819-000 D1256/D1257 Installation Instructions 74-06925-000 D1260 Installation Guide 48101 D1260 Owner’s Manual 50410 D5200 Operation Manual...
  • Page 9: Fcc Rules

    This equipment generates, uses, and can radiate radio If the D9412G/D7412G Control Panels cause harm to frequency energy; and if not installed and used in the telephone network, the telephone company will accordance with the instructions, may cause harmful attempt to notify you in advance.
  • Page 10 D9412G/D7412G | Operation & Installation Guide | 1.0 Introduction EN | 10 Notes: Bosch Security Systems | 10/03 | 43488E...
  • Page 11: Overview

    D9412G/D7412G | Operation & Installation Guide | 2.0 Overview EN | 11 Overview Figure 1: System Configuration D8129 OctoRelay provides alarm D9210B Modules may be and auxilliary relay output. used for access control. (Other functions available.) Each D8128D OctoPOPIT combines D9133TTL-E allows communciation eight POPIT points in one module.
  • Page 12: Specifications

    Current Panel : 500 mA alarm, 200 mA idle Requirements See Section 4.1 Current Rating Chart for Standby Battery Calculations in the D9412G/D7412G Approved Applications Compliance Guide for the current draw requirements of other system components. Power Outputs* All external connections are inherently power-limited except battery terminals.
  • Page 13: Compatible Accessories

    Introduction Terminal 10, Earth Ground. See Section 3.5.2 Ground Fault Detect Enable for information on operating this Eventually, the D9412G will replace the D9412 and function. D9112, and the D7412G will replace the D7412 and D7212. The suffix “G” indicates the control panel’s 2.3.3...
  • Page 14: Netcom Functionality

    D9412G/D7412G | Operation & Installation Guide | 2.0 Overview EN | 14 2.3.4 NetCom Functionality 2.4.3 Communicator The D6600 NetCom System supports data network The control panel uses a built-in digital communicator communications. NetCom allows the D6600 receiver to to send reports to the receiver. The panel transmits...
  • Page 15: Keyswitch

    2.4.6 Access Control 2.4. 1 1 Other Features The D9412G can control eight access doors (each requiring the optional D9210B Wiegand Control D9412G/D7412G Control Panels have many Interface Module) with up to 996 uniquely identified programmable features. Some of the features are listed cards/tokens.
  • Page 16: Available By Separate Order

    D9412G/D7412G | Operation & Installation Guide | 2.0 Overview EN | 16 2.4. 1 3 Available by Separate Order 2.4. 1 4 Listings and Approvals Order the following components separately to complete The D9412G/D7412G Literature Pack includes the a basic 8-point installation.
  • Page 17: Installation

    D9412G/D7412G | Operation & Installation Guide | 3.0 Installation EN | 17 Installation Enclosure Options Mount the control panel assembly in any of the Bosch Before Beginning Security Systems enclosures listed: This section contains a general installation procedure • D8103 Universal Enclosure (tan) and refers to other sections of the document for detailed •...
  • Page 18: Installing The Assembly

    D9412G/D7412G | Operation & Installation Guide | 3.0 Installation EN | 18 Installing the Assembly The 9000 Series Control Panels log and print a Ground Fault event as a Trouble 1. Place the assembly over the inside back of the Point 256.
  • Page 19: Finishing The Installation

    The Section 10.0 Arming Devices for instructions. panel may generate Watchdog Reset and/or Param Fail events. See Watchdog Reset Reports in the D9412G/7412G/ D7212G Installation and Troubleshooting Quick Reference Guide for a description of these events. Always touch Terminal 10, the panel’s earth ground connection, before...
  • Page 20: Power Up

    Install the point chart label for fire or combined fire/burglary systems using verification points. Use the D9412G/D7412G Program Record Sheet to gather the information needed to complete the point chart. Install the label on the enclosure door seen in Figure 2.
  • Page 21: Primary Power Terminals

    When connecting two D1218 Batteries to acknowledges the restoral of power. See the D9412G/ the control panel, both must have the same D7412G Program Entry Guide for additional information capacity (use two 17.2 Ah batteries or two...
  • Page 22: 4.0 Power Supply

    D9412G/D7412G | Operation & Installation Guide | 4.0 Power Supply EN | 22 Figure 5: Non-Power Limited Wiring + AUX BATTERY NEGATI Maximum Charging Current 1.4 Amps. BATTERY POSITIVE ONLY PROGRAMMABLE RELAY A ALARM OUTPUTS Terminals & RELAY B Requires Optional...
  • Page 23: Battery Supervision

    4.0 Power Supply D9412G/D7412G | Operation & Installation Guide | EN | 23 4.2.4 Battery Supervision 4.2.6 Battery Discharge/Recharge Schedule When battery voltage drops to 13.8 VDC, the yellow Table 9: Battery Discharge/Recharge Schedule charging status LED lights. When the battery drops to 12.1 VDC, the red low battery LED lights and the panel...
  • Page 24: Charging Status And Low Battery Leds

    D9412G/D7412G | Operation & Installation Guide | 4.0 Power Supply EN | 24 Charging Status and Low Battery LEDs Table 10: Charging Status and Low Battery LEDs Type LED Color LED State Action Charging Yellow Shows the changing status of the battery. See Figure 6 for location.
  • Page 25: Power Outputs

    D9412G/D7412G | Operation & Installation Guide | 5.0 Power Outputs EN | 25 Power Restricted for Fire and Combined Fire/ Power Outputs Burglary Systems: Use the Fire System Power Formula to Circuit Protection calculate the current available for fire and combined fire/burglary systems (see section 5.4 Programmable...
  • Page 26: Terminals 6 And 7

    D9412G/D7412G | Operation & Installation Guide | 5.0 Power Outputs EN | 26 Incorrect insertion does not damage the relay or the Available Power system; however, the related circuits do not function The system combines the 1.4 A of primary power properly.
  • Page 27: Telephone Connections

    D9412G/D7412G | Operation & Installation Guide | 6.0 Telephone Connections EN | 27 Telephone Connections Figure 8: RJ31X Wiring Registration RJ31X The Bosch Security Systems D9412G/D7412G Control RING (red) TIP (green) Panels are registered with the Federal Communication Commission (FCC) under Part 68, for connection to the public telephone system using an RJ31X or RJ38X jack installed by the local phone company.
  • Page 28: Phone Led (Red)

    D9412G/D7412G Program Entry Guide. the phone line during this process. Once the phone line on the D9412G/D7412G is no longer in use, it begins once again to monitor the phone line. Bad Line May Test OK: The telephone line monitor uses voltage levels to test the status of the phone line.
  • Page 29: Ground Start

    See Phone in the D9412G/D7412G Program Entry Guide for phone supervision and reporting options. To use the Do Not Rely on Relay Labelling: Do not rely on the D928, set the Two Phone Lines prompt to Yes.
  • Page 30: Watchdog Feature

    D9412G/D7412G | Operation & Installation Guide | 6.0 Telephone Connections EN | 30 6. 1 2.3 Watchdog Feature Figure 11: D928 Dual Phone Line Switcher The D928 Watchdog circuit monitors the panel’s CPU for proper operation. If the CPU fails, the buzzer on the D928 sounds, as does the sounder on the panel.
  • Page 31: D928 Status Leds

    6.0 Telephone Connections D9412G/D7412G | Operation & Installation Guide | EN | 31 6. 1 2.5 D928 Status LEDs Four LEDs mounted on the front edge of the D928 Module show the status of AC power for the panel, the status of the two phones lines, and communication failure (see Figure 11).
  • Page 32 D9412G/D7412G | Operation & Installation Guide | 6.0 Telephone Connections EN | 32 Notes: Bosch Security Systems | 10/03 | 43488E...
  • Page 33: On-Board Points

    D9412G/D7412G | Operation & Installation Guide | 7.0 On-Board Points EN | 33 The number of normally-open and/or normally-closed On-Board Points detection devices each sensor loop can supervise is Description Terminals limited only by the resistance on the loop. The total resistance for the wire length and contacts, minus the The panel provides eight on-board points.
  • Page 34: Point Response Time

    D9412G/D7412G | Operation & Installation Guide | 7.0 On-Board Points EN | 34 Point Response Time Wiring Information for Installations Using the Ademco AB-12 The panel scans both on-board and off-board point Bell/Housing sensor loops every 300 milliseconds. The Debounce...
  • Page 35: Figure 13: Wiring For Installation Using The Ademco Ab-12 Bell/Housing

    Model D136 Relay In ALT ALARM RELAY C D9412G Control / Communicator is UL Listed For Central Station, Local, Remote Station and Household ZONEX IN 2 & SW AUX Fire Alarm, and Central Station, Local, Police Station Connect and Household Burglar Alarm.
  • Page 36 D9412G/D7412G | Operation & Installation Guide | 7.0 On-Board Points EN | 36 Notes: Bosch Security Systems | 10/03 | 43488E...
  • Page 37: Off-Board Points

    Terminals 23 and 24 for power (3 and 9 on the D7412G), and if there are POPITs connected to the data expansion and Terminals 25 and 26 (D9412G only), or 27 and 28 bus without a Point Index assigned to it, an Extra Point for data.
  • Page 38: D8125, D8127 And D9127 Popit Modules

    Module to report to the panel. Each D8125 supports up 1. Connect the GND terminal of the D8125 to to 119 POPIT points. Connect two D8125 Modules to Terminal 23 on the D9412G or to Terminal 9 on the the D9412G to bring the combined total number of D7412G.
  • Page 39: Figure 14: Connecting The D8125 Popex To The D9412G Panel

    D9412G/D7412G | Operation & Installation Guide | 8.0 Off-Board Points EN | 39 Figure 14: Connecting the D8125 POPEX to the D9412G Panel Bosch Security Systems | 10/03 | 43488E...
  • Page 40: Figure 15: Connecting The D8125 Popex To The D7412G Panel

    D9412G/D7412G | Operation & Installation Guide | 8.0 Off-Board Points EN | 40 Figure 15: Connecting the D8125 POPEX to the D7412G Panel Bosch Security Systems | 10/03 | 43488E...
  • Page 41: Wiring Data Expansion Loops To Popex Modules

    Remember, a maximum of 119 POPITs can be For the D9412G, Points 73 to 127 and 193 connected to one D8125 on the D9412G; 67 for the to 247 must use the D9127 POPITs. Points D7412G (see Figure 14 and Figure 15).
  • Page 42: Program Record Sheet

    D9412G off-board points are numbered 9 to 127 and 129 Sheet contains the switch settings for the D8127 POPITs. to 247 (D7412G uses Points 9 to 75 only). The D9412G Switches are numbered 1 to 6, left to right on the D8127 reserves Points 128 and 248 for internal use.
  • Page 43: D8128D Octopopit Module

    A maximum of thirty D8128D Modules can be connected to the D9412G Control Panel. A maximum of nine D8128Ds can be connected to the D7412G Control Panel (three points can be used on the last OCTOPopit).
  • Page 44: Setting The Octopopit Switches

    Input Switch 8 to the OPEN position. Mounting Bracket to install OctoPOPITs in enclosures with no module-mounting locations available. D9412G uses Points 9 to 127 on ZONEX 1 and Points 129 to 247 on ZONEX 2. 1. Align the OctoPOPIT module using any of the four...
  • Page 45: Wiring Octopopits

    D8128D to the control panel via the the control panel. There are two methods for connecting OctoPOPIT’s terminal strip. the D8128D to a control panel: wire the OctoPOPIT to Figure 18: Connecting D8128D OctoPOPITs to the D9412G Reset Pin Disable All Except Battery Charging And Programming...
  • Page 46: Figure 19: Connecting D8128D Octopopits To The D7412G

    D9412G/D7412G | Operation & Installation Guide | 8.0 Off-Board Points EN | 46 Figure 19: Connecting D8128D OctoPOPITs to the D7412G Low Battery Battery amming E CONNECTIONS CLASS 2 TRANS POWER + 16.5 VAC 40 VAC Model D1640 Internally Fuse...
  • Page 47: Octopopit Sensor Loops

    D9412G/D7412G | Operation & Installation Guide | 8.0 Off-Board Points EN | 47 8.4.7 OctoPOPIT Sensor Loops Table 14: Terminal Strip Connections Only the resistance on the loop limits the number of normally-open and/or normally-closed detection devices D8128D D9412G D7412G each sensor loop can supervise.
  • Page 48: Testing Off-Board Points

    D9412G/D7412G | Operation & Installation Guide | 8.0 Off-Board Points EN | 48 Testing Off-Board Points Figure 21: D81282D OctoPOPIT Sensor Loops Use the Service Walk Test to test off-board points. See the D9412G/D7412G/D7212G Installation and Troubleshooting Quick Reference Guide for instructions. Test to ensure all off-board points operate properly.
  • Page 49: Off-Board Relays

    When the output is not activated, 65 to 128 connect to ZONEX 2 (D9412G only), there is continuity between the normally-closed and Terminal 26 on the D9412G. See Figure 22 and Figure 23. common terminals. Alarm output, auxiliary relay, sensor reset, arming 9.
  • Page 50: Figure 22: D8129 Connections To The D9412G

    D9412G/D7412G | Operation & Installation Guide | 9.0 Off-Board Relays EN | 50 Figure 22: D8129 Connections to the D9412G Reset Pin Disable All Except Battery Charging And Programming PERIPHERAL DEVICE CONNECTIONS POWER + YELLOW DATA BUS A DATA GREEN...
  • Page 51: D811 Arm Status Relay Module

    D811 is connected to ZONEX 1, Terminal 28, use relay number 53 for the relay output. If the D811 is connected to ZONEX 2, Terminal 26 on the D9412G, use relay number 117 for the relay output. D811 Modules connect as shown in Figure 24 and Figure 25.
  • Page 52: Figure 24: D811 Module Wiring To The D7412G

    D9412G/D7412G | Operation & Installation Guide | 9.0 Off-Board Relays EN | 52 Figure 24: D811 Module Wiring to the D9412G Reset Pin Disable All Except Battery Charging And Programming PERIPHERAL DEVICE CONNECTIONS POWER + YELLOW DATA BUS A GREEN...
  • Page 53: 10.0 Arming Devices

    Table 17 shows the correct switch setting for each 10.2 Command Center Terminals address. The Bosch Security Systems command center is a 4-wire Table 17: Command Center Address Settings powered device used to arm and disarm areas, annunciate complete system status, initiate system tests, and control many functions of the security system.
  • Page 54: Figure 26: Power At Command Centers

    D9412G/D7412G | Operation & Installation Guide | 10.0 Arming Devices EN | 54 Limit command centers to 610 m (2000 ft.) per run; Control Panel and D8132 (or other power limit D9210B Modules to 457 m (1500 ft.) per run supply) must share COMMON: Note that (762 m [2,500 ft.] if using an external power supply),...
  • Page 55: D268/D269 Independent Zone Control, D279A Independent Zone Control

    All faulted points are force armed, be programmed to activate arming status LEDs for regardless of the entry in the FA Bypass Max program keyswitch arming stations. See Relays in the D9412G/ item. See Point Assignments in the D9412G/D7412G D7412G Program Entry Guide.
  • Page 56 10.0 Arming Devices D9412G/D7412G | Operation & Installation Guide | EN | 56 Notes: Bosch Security Systems | 10/03 | 43488E...
  • Page 57: 11.0 Sdi Devices

    11.3 D9131A Parallel Printer Interface Using Wiegand style cards or tokens, the D9210B can allow access for up to 996 cards/tokens on the D9412G, Module 396 on the D7412G. User access authority can be The Bosch Security Systems D9131A Parallel Printer...
  • Page 58: Sdi Address 80

    Used as an External Modem Figure 28: D9133 Jumper Settings The D9133DC can operate as an external modem when using RAM IV with the panel. See the D9412G/D7412G Program Entry Guide for programming details. Bosch Security Systems | 10/03 | 43488E...
  • Page 59: D9133Ttl-E Network Interface Module

    D9412G/D7412G | Operation & Installation Guide | 11.0 SDI Devices EN | 59 11.6.2 D9133TTL-E Network Interface Module 11.6.3 Address Settings The Bosch Security Systems D9133TTL-E Network Place a jumper over Pin 8 for the D9133TTL-E Interface Module is a 4-wire powered SDI device that...
  • Page 60 D9412G/D7412G | Operation & Installation Guide | 11.0 SDI Devices EN | 60 Notes: Bosch Security Systems | 10/03 | 43488E...
  • Page 61: Programmer/Accessory Connections

    D9412G/D7412G | Operation & Installation Guide | 12.0 Programmer/Accessory Connections EN | 61 12.0 Programmer/Accessory 12.2 Accessory Connector Connections Use the accessory connector to connect the panel to the D928 Dual Phone Line Switcher. The accessory 12.1 Programmer Connector connector is on the bottom right corner of the I/O board (see Figure 31).
  • Page 62 D9412G/D7412G | Operation & Installation Guide | 12.0 Programmer/Accessory Connections EN | 62 Notes: Bosch Security Systems | 10/03 | 43488E...
  • Page 63: 13.0 Faceplates

    D9412G/D7412G | Operation & Installation Guide | 13.0 Faceplates EN | 63 13.0 Faceplates 13.1 D9412G Faceplate Figure 32: D9412G Faceplate 1 - Charging status LED (yellow) 8 - Phone LED (red) 2 - Low Battery LED (red) 9 - Point 8 ground fault detect enable/disable...
  • Page 64: D7412G Faceplate

    D9412G/D7412G | Operation & Installation Guide | 13.0 Faceplates EN | 64 13.2 D7412G Faceplate Figure 33: D7412G Faceplate 1 - Charging status LED (yellow) 8 - Phone LED (red) 2 - Low Battery LED (red) 9 - Point 8 ground fault detect enable/disable...
  • Page 65: System Wiring Diagrams, Issue A

    18.0 Ah In ALT ALARM RELAY C D9412G Control / Communicator is UL Listed For Central Station, Local, Remote Station and Household ZONEX IN 2 & SW AUX Fire Alarm, and Central Station, Local, Police Station Connect and Household Burglar Alarm.
  • Page 66: D9412G Control Panel, 2 Of 3

    Model D136 Relay In ALT ALARM RELAY C D9412G Control / Communicator is UL Listed For Central Station, Local, Remote Station and Household ZONEX IN 2 & SW AUX Fire Alarm, and Central Station, Local, Police Station Connect and Household Burglar Alarm.
  • Page 67: D9412G Control Panel, 2 Of 3

    In ALT ALARM RELAY C & SW AUX D9412G Control / Communicator is UL Listed For Central Station, Local, Remote Station and Household ZONEX IN 2 Fire Alarm, and Central Station, Local, Police Station Connect and Household Burglar Alarm. System is Intended To Be Checked By A Qualified Technician At Least Every 3 Years.
  • Page 68: D7412G Control Panel, 1 Of 3

    The Power Supply Provides a Maximum of 1.4 Amps For The Control POWER + 16.5 VAC 40 VA 60 Hz Panel and All Accessory Devices. For System Loading, See D9412G/D7412G Operation Model D1640 and Installation Guide (P/N:43488___). Internally Fused - Do Not short...
  • Page 69: D7412G Control Panel, 2 Of 3

    The Power Supply Provides a Maximum of 1.4 Amps For The Control POWER + 16.5 VAC 40 VA 60 Hz Panel and All Accessory Devices. For System Loading, See D9412G/D7412G Operation Model D1640 and Installation Guide (P/N:43488___). Internally Fused - Do Not short...
  • Page 70: D7412G Control Panel, 3 Of 3

    The Power Supply Provides a Maximum of 1.4 Amps For The Control POWER + 16.5 VAC 40 VA 60 Hz Panel and All Accessory Devices. For System Loading, See D9412G/D7412G Operation Model D1640 and Installation Guide (P/N:43488___). Internally Fused - Do Not short...
  • Page 71: Point Address Charts

    D9412G/D7412G | Operation & Installation Guide | Appendix B EN | 71 Appendix B: Point Address Charts ZONEX 1, Points 9 to 127 (D9412G); ZONEX 1, Points 9 to 75 (D7412G) D8127 or D9127 POPITs can be used for Points 9 to 72;...
  • Page 72: Zonex 2, Points 129 To 247 (D9412G Only)

    D9412G/D7412G | Operation & Installation Guide | Appendix B EN | 72 ZONEX 2, Points 129 to 247 (D9412G Only) Place the labels on the base of the POPIT. Do not attach labels to the POPIT cover. A number in the switch column indicates that the switch is set to ON.
  • Page 73: Index

    D9412G/D7412G | Operation & Installation Guide | Index EN | 73 Index Access Control ..............15, 57 D1218 Battery ................21 Standard Features ..............15 D125B ..................43 Accessories .................. 13 D129 ..................... 43 Accessory Connector ..............61 D192C ..................43 Accounts D192G ..................
  • Page 74 D9412G/D7412G | Operation & Installation Guide | Index EN | 74 Faceplates Phone ..................27 D7412G ................... 64 Phone Cords ................ 27, 30 D9412G ................... 63 Phone Lines ................ 19, 27 Dialing Format ..............28 Registration Number ............27 Dual Phone Line Switcher ..........29 FCC Rules ..................
  • Page 75 Index D9412G/D7412G | Operation & Installation Guide | EN | 75 RAM IV ................15, 20 Warnings ..................8 Related Documentation ............8 Watchdog Feature ..............30 Remote Account Manager ..........15, 20 Wiring ................... 19 Replacing Batteries ..............22 Command Centers ..............
  • Page 76 Bosch Security Systems 130 Perinton Parkway Fairport, NY 14450-9199 USA www.boschsecurity.us Customer Service: (800) 289-0096 Technical Support: (888) 886-6189 © 2003 Bosch Security Systems 43488E...

This manual is also suitable for:

D7412g

Table of Contents