Epson TM-L60 Operator's Manual page 55

Thermal line printer
Hide thumbs Also See for TM-L60:
Table of Contents

Advertisement

n1 + n2 x 256 = 1
[Default]
[Reference]
GS CO, GS Cl, GS c, GS C;
GSC; N1; N2; N3; N4; N5;
[Name]
Select count mode (B)
[Format]
<1D>H<43>H<3B>H<N1><3B>H<N2><3B>H<N3><3B>H
<N4><3B>H<N5><3B>H
[Range]
0
0 N2 65535
0 N3
0
0 N5 65535
[Description]
Select count mode of the serial number counter and specifies the
starting value of the counter.
W i t h c o u n t i n g u p
Counts up if N1<N2, N3
l
l
W i t h c o u n t i n g d o w n
Counts down if N1>N2, N3 # 0, and N4
l
l
To stop counting
Stops counting when N1 = N2, N3 = 0, or N4 = 0.
l
l
l
l
[Notes]
l
l
l
l
W i t h c o u n t i n g u p
l
N1
65535
255
N4
255
N1 means the minimum value of the counter, and N2 the
maximum value.
N1 means the maximum value of the counter, and N2 the
minimum value.
N3 indicates stepping amount while counting up or down.
N4 indicates repetition number with the counter value fixed.
N5 indicates the counter value.
When this command is issued, the inner counter that counts the
repetition number with counter value fixed will be cleared.
N7 to N5 can be omitted. If omitted, those parameter values will
be kept unchanged.
N7 to N5 cannot contain characters except O-9.
If incorrect syntax is used, the corresponding parameter setting
will have no effect and the data after that will be processed as
normal data.
If the counting up reaches a value exceeding the maximum, it
will be resumed with the minimum.
0, and N4
0.
4 9