Panasonic AMK3000P22 Installation Manual page 48

Mk300 series. 1-phase 200v(0.2kw-2.2kw), 3-phase 400v(0.75kw-15kw)
Table of Contents

Advertisement

No.
Function name
SW5 Function
P105
Selection
SW6 Function
P106
Selection
Pulse Train Input
P107
Frequency
Pulse Train Input
P108
Filter
47
Changes
during RUN
(*2)
0: No setting
1(r1): Multi-step speed
2(r2): Reset
3(r3): Reset lock
4(r4): Jogging selection
5(r5): Stop by external fault
6(r6): Parameter setting disabled
7(r7): Coast-to-stop
8(r8): Switching of frequency signal
9(r9): 2nd characteristics selection
10(r10): Switching of PID control
11(r11): 3-wire stop command
12(r12): Speed search
13(r13): Winding mode pause
14(r14): Winding length input mode
15(r15): Winding length clear
16(r16): Run/stop
17(r17): Forward/reverse run
18(r18): Forward run by jogging
19(r19): Reverse run by jogging
20(r20): Frequency memory setting
(*2)
0: No setting
1(r1): Multi-step speed
2(r2): Reset
3(r3): Reset lock
4(r4): Jogging selection
5(r5): Stop by external fault
6(r6): Parameter setting disabled
7(r7): Coast-to-stop
8(r8): Switching of frequency signal
9(r9): 2nd characteristics selection
10(r10): Switching of PID control
11(r11): 3-wire stop command
12(r12): Speed search
13(r13): Winding mode pause
14(r14): Winding length input mode
15(r15): Winding length clear
16(r16): Run/stop
17(r17): Forward/reverse run
18(r18): Forward run by jogging
19(r19): Reverse run by jogging
20(r20): Winding length
1.0 to 40.0
10 to 100
Setting range
Initial
Unit
value
0
0
1[kHz]
1.0
1[times]
50

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents