5.4 Installing the Magnetic Clamping Fixture - MCF

The Magnetic Clamping Fixture (MCF) is used to fasten transducers to the pipe at the proper spacing without chains or
straps. The MCF is used on ferrous pipe materials only.
Different fixtures are used for a single- and double-traverse installation. Each type of MCF has magnets at either end of
the fixtures. When the magnets are turned ON, the fixture magnetically "clamps" to the pipe wall.
To properly mount the MCF, you should become familiar with the components of each type of fixture.
5.4a Identifying the MCF Components
Refer to Figure 11 to identify these components, then refer to one of the following sections to install the clamping
fixture:
Double-traverse Method - page 31
Single-traverse Method - page 33
Optional Safety Chain
30
Transducer Block
Pressure Bolt
Counter Nut
Figure 11: Transducer Block and Magnetic Block
Magnetic Block
Thumbscrews
Rails
C-PT Ultrasonic Flow Transducer Installation Guide
ON/OFF Switch