ABB ME ASU RE M E N T & ANA LY T ICS | DATA SHEE T
WaterMaster
Electromagnetic flowmeter

Advertisement

loading

Summary of Contents for ABB WaterMaster

  • Page 1 — ABB ME ASU RE M E N T & ANA LY T ICS | DATA SHEE T WaterMaster Electromagnetic flowmeter...
  • Page 2 WATERMA STE R EL ECT ROMAG NET IC F LOWME T E R | DS / W M - E N RE V. Y — Measurement made easy The perfect fit for all water and waste water applications — State-of-the-art technology •...
  • Page 3 Setting the standard for the Water Industry The 'Easy Setup' function reliably guides unpracticed users The WaterMaster range, available in sizes 10 to 2400 mm (3/8 through the menu step by step. The smart key based to 96 in.), is designed specifically for use on the many diverse functionality makes handling a breeze –...
  • Page 4 (options are available for AC and DC supplies) metering pits that are susceptible to flooding. • comprehensive self-diagnostics compliant with A unique feature of the WaterMaster sensors is that sizes NAMUR NE107 DN40 to DN2400 (11/2 to 96 in. NB) are buriable; installation •...
  • Page 5 Instruments Directive (MID) 2004/22/EC, that covers putting into use water flowmeters for certain applications. MID WaterMaster is secured against tamping and is available as an option, along with fingerprinting for ABB VeriMaster in situ verification product, with certificate printout to ±1 % accuracy.
  • Page 6 /h (GPM) Although OIML R49 does not define the flow accuracy below Q1, WaterMaster continues to measure flow at lower flow rates down to a cutoff velocity of ±5 mm/s (±0.2 in./s). The accuracy between cutoff and Q1 is typically ±0.9 mm/s (±0.04. in./s).
  • Page 7 WATE R MA STE R E LE CTR OM AG N E TI C F LOW ME T ER | D S / WM-E N R EV. Y WaterMaster optimized full-bore meter (FEV) / full-bore meters (FEF, FEW) flow performance – m Standard Calibration –...
  • Page 8 WATE RM A ST E R EL EC T RO M AG N ET IC F LOWME T ER | DS / WM-E N RE V. Y — …Specification WaterMaster optimized full-bore meter (FEV) / full-bore meters (FEF, FEW) flow performance – gal/min Standard Calibration 0.4 % Class 2 High Accuracy Calibration 0.2 % Class 1 NPS/NB (DN) 0.4%...
  • Page 9 FER (DN40 to 600 20 mm armored glands [11/2 to 24in. NB]) Sensor cable ABB WaterMaster cable available in two forms – standard and armored Maximum length 200 m (660 ft.) Suspended solids Suspended solids percentage of process medium should...
  • Page 10 WATE RM A ST E R EL EC T RO M AG N ET IC F LOWME T ER | DS / WM-E N RE V. Y — …Specification – Sensor Non-wetted parts Flange material Carbon steel DN20 to DN2400 (3/4 to 96 in. NB) Stainless steel DN10 to DN2400 (3/8 to 96 in.
  • Page 11 1 and 2 (FEV DN40 to 200 [11/2 to 8 in.NB]). Copies of accuracy certification are available on request. WaterMaster (FEV DN40 to 200 [11/2 to 8 in.NB]) has been * When installed, do not leave galvanically isolated circuits type examined under directive MID 2004/22/EC, Annex MI- (pulse and current) floating.
  • Page 12 WATE RM A ST E R EL EC T RO M AG N ET IC F LOWME T ER | DS / WM-E N RE V. Y — Transmitter connections Transmitter terminal connections overview This section is intended to give an overview of installation of a flowmeter. For Installation requirements, technical information and Health and safety precautions –...
  • Page 13 WATE R MA STE R E LE CTR OM AG N E TI C F LOW ME T ER | D S / WM-E N R EV. Y Power supply connections AC power supply Power supply indicator LED *AC Fuse F1 250 mA Type T (see table below for suppliers) Internal earth screws** **Can be used as a...
  • Page 14 WATE RM A ST E R EL EC T RO M AG N ET IC F LOWME T ER | DS / WM-E N RE V. Y — …Transmitter connections Configuration DIP switches Transmitter module identification Note. The communications bus type is HART FEX100 if not Three configuration DIP switches are mounted on the transmitter backplane board.
  • Page 15 WATE RM A ST E R EL EC T RO M AG N ET IC F LOWME T ER | DS / WM-E N RE V. Y — Output connections Frequency outputs Alarm outputs PLC or Datalogger XX XX XX XX 42 41 51 61 Terminal connection IDs COM DO3 are HART- / PROFIBUS- /...
  • Page 16 Fwd – Rev – Screen clamp Note. • WaterMaster digital outputs are NPN optocoupled Test point access transistors used as switches. • Maximum allowed voltage at collector is 30 V DC Note. A typical DVM probe can access (fit) the PCB's test •...
  • Page 17 WaterMaster System integration Slave FEX100-DP level WaterMaster can be integrated into control systems and configuration devices using any Frame application, such as DP / PA Link ABB AssetVision or similar third-party applications. ABB Device Type Managers (DTMs) for WaterMaster provide a...
  • Page 18 1000 m (3280 ft.). Where 4-wire cabling is used as a 2-wire cabling system the maximum length must be The ABB GSD file (Ident No. 3431) is divided into 2 sections: divided by 2. The tap cables must be short, never more than •...
  • Page 19 WATE RM A ST E R EL EC T RO M AG N ET IC F LOWME T ER | DS / WM-E N RE V. Y — Installation requirements Mounting This section is intended to give an overview of installation of The installation conditions shown below must be observed to a flowmeter.
  • Page 20 0 x DN (FER) 0 x DN (FER) 5 x DN (FEV) 0 x DN (FEV) Ensure a maximum 6 % dry solids content flow through pipe – for higher dry solids content, refer to ABB’s ProcessMaster range. ≤6 % (max.) dry solids...
  • Page 21 WATE RM A ST E R EL EC T RO M AG N ET IC F LOWME T ER | DS / WM-E N RE V. Y — Transmitter dimensions Integral transmitter Dimensions in mm (in.) 98 (3.8) 202 (8.0) 118 (4.6) Remote transmitter Dimensions in mm (in.)
  • Page 22 WATE RM A ST E R EL EC T RO M AG N ET IC F LOWME T ER | DS / WM-E N RE V. Y — Sensor dimensions FEW – DN10 to 125 (⅜ to 5 in. NB) Dimensions in mm (in.) Ø104 (4.11) Remote transmitter...
  • Page 23 WATE R MA STE R E LE CTR OM AG N E TI C F LOW ME T ER | D S / WM-E N R EV. Y Dimensions in mm (in.) Approx. weight in kg (lb) Process connection type Integral Remote JIS10K...
  • Page 24 WATE RM A ST E R EL EC T RO M AG N ET IC F LOWME T ER | DS / WM-E N RE V. Y — …Sensor dimensions FEW – DN150 to 400 (6 to 16 in. NB) Dimensions in mm (in.) Ø104 (4.11)
  • Page 25 WATE R MA STE R E LE CTR OM AG N E TI C F LOW ME T ER | D S / WM-E N R EV. Y Dimensions in mm (in.) Approx. weight in kg (lb) Process connection type Integral Remote PN10 to 16...
  • Page 26: Table Of Contents

    WATE RM A ST E R EL EC T RO M AG N ET IC F LOWME T ER | DS / WM-E N RE V. Y — …Sensor dimensions FEW – DN450 to 2400 (18 to 96 in. NB) Dimensions in mm (in.) Ø104 Remote transmitter...
  • Page 27 WATE R MA STE R E LE CTR OM AG N E TI C F LOW ME T ER | D S / WM-E N R EV. Y Dimensions in mm (in.) Approx. weight in kg (lb) Process connection type L (1.0D) L (1.3D) Integral...
  • Page 28 WATE RM A ST E R EL EC T RO M AG N ET IC F LOWME T ER | DS / WM-E N RE V. Y — …Sensor dimensions …FEW – DN450 to 2400 (18 to 96 in. NB) Dimensions in mm (in.) Ø104 Remote transmitter...
  • Page 29: (18 In.) As4087 Pn35

    WATE R MA STE R E LE CTR OM AG N E TI C F LOW ME T ER | D S / WM-E N R EV. Y Dimensions in mm (in.) Approx. weight in kg (lb) Process connection type L (1.0D) L (1.3D) Integral...
  • Page 30: As4087 Pn16

    283.7 (11.17) 235.7 (9.28) 150 (5.91) 67 (147.4) 66 (145.2) (8 in.) AS2129 TABLE C, D, E, F AS4087 PN14, 16, 21 WaterMaster integral / remote FEV – DN40 to 200 (11/2 to 8 in.) cast iron sensor dimensions / weights...
  • Page 31 WATE R MA STE R E LE CTR OM AG N E TI C F LOW ME T ER | D S / WM-E N R EV. Y Dimensions in mm (in.) Approx. weight in kg (lb) Process connection type Integral Remote EN1092-1 PN10, PN40...
  • Page 32 WATE RM A ST E R EL EC T RO M AG N ET IC F LOWME T ER | DS / WM-E N RE V. Y — …Sensor dimensions FER – DN40 to 300 (11/2 to 12 in. NB) Ø104 (4.11) Remote transmitter...
  • Page 33 WATE R MA STE R E LE CTR OM AG N E TI C F LOW ME T ER | D S / WM-E N R EV. Y Dimensions in mm (in.) Approx. weight in kg (lb) Process connection type Integral Remote EN1092-1 PN10, 16, 25, 40...
  • Page 34 WATE RM A ST E R EL EC T RO M AG N ET IC F LOWME T ER | DS / WM-E N RE V. Y — … Sensor dimensions FER – DN350 to 600 (14 to 24 in. NB) remote sensor Ø104 (4.11) 86 (3.4)
  • Page 35: Dn500

    WATE R MA STE R E LE CTR OM AG N E TI C F LOW ME T ER | D S / WM-E N R EV. Y Dimensions in mm (in.) Approx. weight in kg (lb) Process connection type Remote EN1092-1 PN10 505 (19.88)
  • Page 36 WATE RM A ST E R EL EC T RO M AG N ET IC F LOWME T ER | DS / WM-E N RE V. Y — … Sensor dimensions FEF – DN250 to 600 (10 to 24 in. NB) Ø104 (4.11) 86 (3.4)
  • Page 37 WATE R MA STE R E LE CTR OM AG N E TI C F LOW ME T ER | D S / WM-E N R EV. Y Dimensions in mm (in.) Process connection type Approx. weight in kg (lb) ASME B16.5 CLASS 150 405 (15.94) 450 (17.72)
  • Page 38 WATE RM A ST E R EL EC T RO M AG N ET IC F LOWME T ER | DS / WM-E N RE V. Y — … Sensor dimensions …FEF – DN250 to 600 (10 to 24 in. NB) Ø104 (4.11) 86 (3.4)
  • Page 39: (20 In.)

    WATE R MA STE R E LE CTR OM AG N E TI C F LOW ME T ER | D S / WM-E N R EV. Y Dimensions in mm (in.) Process connection type Approx. weight in kg (lb) ASME B16.5 CLASS 150 635 (25.00) ASME B16.5 CLASS 300...
  • Page 40 WATE RM A ST E R EL EC T RO M AG N ET IC F LOWME T ER | DS / WM-E N RE V. Y — Ordering information Electromagnetic flowmeter WaterMaster – FEW11, FEW12 and FEW18 Product coding field number 1 … 5 6 7 …...
  • Page 41 FEW12 Full bore sensor only – FEW18 for use with WaterMaster transmitter / remote Protection class transmitter / protection class sensor IP67 (NEMA 4X) / IP67 (NEMA 4X) – cable not fitted and potted to sensor IP67 (NEMA 4X) / IP67 (NEMA 4X) – cable fitted and potted to sensor Cable conduits* M20 x 1.5 (plastic)
  • Page 42 — …Ordering information Electromagnetic flowmeter WaterMaster – FEV11, FEV12 and FEV18 Product coding field number 1 … 5 6 7 … 9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27...
  • Page 43 Flowmeter system, optimized full bore, remote mount FEV12 Optimized full bore sensor only, FEV18 for use with WaterMaster transmitter / remote Temperature range installation / ambient temperature range Standard design / –20 to 60 °C (–4 to 140 °F) Nameplate...
  • Page 44 — …Ordering information …Electromagnetic flowmeter WaterMaster – FEV11, FEV12 and FEV18 Product coding field number 1 … 5 6 7 … 9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27...
  • Page 45 Product coding field number 1 … 5 6 7 … 9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27 Flowmeter system, full bore, remote mount FEF12 Full bore sensor only, FEF18 for use with WaterMaster transmitter / remote Design Non-hazardous areas Hazardous areas (DN≥700 [27 in. NB]) Bore diameter DN250 (10 in.)
  • Page 46 — …Ordering information … Electromagnetic flowmeter WaterMaster FEF12 and FEF18 Product coding field number 1 … 5 6 7 … 9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27 Flowmeter system, full bore, remote mount...
  • Page 47 WATE R MA STE R E LE CTR OM AG N E TI C F LOW ME T ER | D S / WM-E N R EV. Y Electromagnetic flowmeter WaterMaster – FEW31, FEW32 and FEW38 Product coding field number 1 … 5 6 7 …...
  • Page 48 — …Ordering information … Electromagnetic flowmeter WaterMaster – FEW31, FEW32 and FEW38 Product coding field number 1 … 5 6 7 … 9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27 Flowmeter system –...
  • Page 49 FEW32 Full bore sensor only – FEW38 for use with WaterMaster transmitter / remote Protection class transmitter / protection class sensor IP67 (NEMA 4X) / IP67 (NEMA 4X) – cable not fitted and not potted to sensor IP 67 (NEMA 4x) / IP68 (NEMA 6P) – cable not fitted and not potted to sensor IP 67 (NEMA 4x) / IP68 (NEMA 6P) –...
  • Page 50 WATE RM A ST E R EL EC T RO M AG N ET IC F LOWME T ER | DS / WM-E N RE V. Y — …Ordering information WaterMaster FER reduced-bore sensor flowmeter series Product coding field number 1 … 6 7 … 9 10 14,15 16 17 18 19 20 21 22 23 24 25 26 27 WaterMaster system.
  • Page 51 WaterMaster system. Reduced-bore sensor FER121 with remote mounted transmitter WaterMaster system. Reduced-bore sensor FER111 with integral transmitter WaterMaster reduced-bore sensor only, remote mount, FER181 without transmitter Calibration type Class 2 calibration – standard accuracy 0.4 % Class 1 calibration – high accuracy 0.2 Extended range, class 1 calibration –...
  • Page 52 WATE RM A ST E R EL EC T RO M AG N ET IC F LOWME T ER | DS / WM-E N RE V. Y — …Ordering information Electromagnetic flowmeter transmitter for WaterMaster FET10 and FET12 Product coding field number 1 … 5...
  • Page 53 Microsoft is a registered trademark of Microsoft Corporation Accessory Item number in the United States and/or other countries WaterMaster AC Fuse F1 Type T 250 mA A/S TR5 B20411 WaterMaster DC Fuse F2 Type T 2 A A/S TR5 B20412...
  • Page 54 WATERMA STE R EL ECT ROMAG NET IC F LOWME T E R | DS / W M - E N RE V. Y — Notes Sales Service Software...
  • Page 55 WATE RMA STER ELEC TROMAGN E T IC F LOWM E T E R | DS / W M- E N RE V. Y...
  • Page 56 We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB. © ABB 2017...