Hitachi Compute Rack CR 210H User Manual page 71

Hide thumbs Also See for Compute Rack CR 210H:
Table of Contents

Advertisement

Error message
The native configuration is no longer
supported by the current controller settings.
Please ensure that correct controller,
iButton or key vault is being used.
If you continue, the configuration will be
marked foreign and part of it may be
imported if possible.
Press any key to continue.
The battery is currently discharged or
disconnected. Verify the connection and
allow 30 minutes for charging.
If the battery is properly connected and it
has not returned to operational state after
30 minutes of charging, contact technical
support for additional assistance.
Press D to disable this warning (if your
controller does not have a battery).
The battery is currently discharged or
disconnected. VDs configured in write-back
mode will run in write-through mode to
protect your data, and will return to
write-back policy when the battery is
operational.
If VDs have not returned to write-back mode
after 30 minutes of charging then contact
technical support for additional assistance.
The following VD is affected: X.
Press any key to continue.
Two BBUs are connected to the adapter.
This is not a supported configuration.
Battery and caching operations are disabled.
Remove one BBU and reboot to restore
battery and caching operations.
If dirty cache is lost in this boot, that could
have been because of dual battery presence.
Firmware did not find valid NVDATA image.
Program valid NVDATA image and restart
your system.
Press any key to continue.
IR to MR Migration failed.
Press any key to continue with MR defined
NVDATA values.
There are offline or missing virtual drives
with preserved cache.
Check the cables and ensure that all drives
are present. Press any key to enter the
configuration utility.
There are offline or missing virtual drives
with preserved cache.
Check the cables and ensure that all drives
are present.
Hitachi Compute Rack 210H User's Guide
The original configuration information is
not supported for setup of the disk array
controller.
The cache backup module information is
illegal.
The cache backup module information is
illegal.
The cache backup module information is
illegal.
Firmware did not find valid NVDATA
image. Program valid NVDATA image
and restart your system.
Press any key to continue.
Migration is not supported.
No logical drive is found.
No logical drive is found.
Troubleshooting
Description
Action
(*1)
(*1)
(*1)
(*1)
(*1)
(*1)
(*1)
(*1)
6-13