Bus Address Settings - Bosch B426 Installation And Operation Manual

Conettix ethernet communication module
Table of Contents

Advertisement

Conettix Ethernet Communication Module
3.2

Bus address settings

The address switch determines the bus type and the module's address on the bus. The control
panel uses the address for communications. Use a slotted screwdriver to set the address
switch.
Notice!
The module reads the address switch setting only during module power up. If you change the
setting after you apply power to the module, you must cycle the power to the module in order
for the new setting to take effect.
The B426 address switch provides the value for the module's address. The figure below shows
the address switch setting for address 1. Refer to the following table for panel-specific
settings.
Figure 3.3: Address switch set to address 1
Control panels
B9512G/B8512G, B6512/
B5512/B4512/B3512, GV4,
Solution 2000/3000
B9512G/B8512G, GV4,
Solution 2000/3000
GV4, GV3, GV2, D9412G/
D7412G/D7212G v6.3 or
higher
GV4, GV3, GV2, D9412G/
D7412G/D7212G v6.3 or
higher
GV4, GV3
FPD-7024 v1.06+,
DS7240V2, DS7220V2, Easy
Series V3+, AMAX Series,
CMS Series
DS7400Xi
DS7400Xi
FPD-7024, AMAX Series,
CMS Series
Tab. 3.1: B426 address switch settings
Bosch Security Systems, Inc.
Switch
Control panel
position
address
1
1
2
2
3
80
4
88
5
92
6
134
7
13
8
14
9
250
Installation and Operation Guide
System overview | en
Bus type
Function
SDI2
Automation, Remote
Programming, or
Reporting
SDI
Automation
Reporting or Remote
Programming
Option
Reporting
Reporting or Remote
Programming
2016.08 | 08 | F.01U.266.226
9