ABB ACS800-U4 Hardware Manual page 5

Drive modules
Hide thumbs Also See for ACS800-U4:
Table of Contents

Advertisement

Update Notice
The notice concerns the following ACS800-04 Drive
Modules (0.55 to 200 kW) and ACS800-U4 Drive Modules
(0.75 to 200 HP) Hardware Manuals:
Code
Revision
3AFE68372984
E
3AFE68449995
E
3AFE68449979
E
3AFE68450004
E
3AFE68449987
E
NEW (page 6): Safety / Installation and maintenance work
• After maintaining or modifying a drive safety circuit or changing circuit boards
inside the module, retest the functioning of the safety circuit according to the
start-up instructions.
• Do not change the electrical installations of the drive except for the essential
control and power connections. Changes may affect the safety performance or
operation of the drive unexpectedly. All customer-made changes are on the
customer's responsibility.
[...]
Note:
• The Safe torque off function (option +Q967) does not remove the voltage from the
main and auxiliary circuits.
CHANGED (page 10): Safety / Permanent magnet motor
• Ensure that the motor cannot rotate during work. Prevent the start-up of any
drives in the same mechanical group by opening the Prevention of unexpected
start switch (option +Q950) or the Safe torque off switch (option +Q967) and
padlocking it. Make sure that no other system, like hydraulic crawling drives, are
able to rotate the motor directly or through any mechanical connection like felt,
nip, rope, etc.
NEW (page 21): Terms and abbreviations
The following term has been added to the Terms and abbreviations table:
Term/
Abbreviation
ASTO
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Language
English
EN
German
DE
Spanish
ES
French
FR
Italian
IT
Explanation
An optional board within inverter modules used to implement the Safe torque off
function (option +Q967).
Code: 3AUA0000068979 Rev B
Valid: from 01.09.2010 until the release of the next revision of
the manual
Contents:
The headings in this update notice refer to the modified
subsections in the original English manual. Each heading also
includes a page number and a classifier NEW, CHANGED, or
DELETED. The page number refers to the page number in the
original English manual. The classifier describes the type of
the modification.