6 Absolute Position Detection System Alarms (Z7*)
6Absolute Position Detection System Alarms (Z7*)
Z70

Abs posn base set incomplete

Details
Zero point initialization is incomplete. Otherwise, the spindle was removed.
Remedy
Complete zero point initialization.
(Note) To release alarm "Z70 Abs data error", enter the parameter data output when establishing the absolute
position and turn ON the power again. For the rotary axis, however, the alarm cannot be released by
entering the parameter data.
Zero point initialization: Required
Z70

Absolute position lost

Details
The absolute position basic point data saved in the NC has been damaged.
Remedy
Set the parameters. If the basic point data is not restored by setting the parameters, perform zero point initial-
ization.
(Note) To release alarm "Z70 Abs data error", enter the parameter data output when establishing the absolute
position and turn ON the power again. For the rotary axis, however, the alarm cannot be released by
entering the parameter data.
Zero point initialization: (Required)
Z70

Abs posn param changed

Details
Any of the parameters for absolute position detection has been changed.
#1003 iunit
#1017 rot
#1018 ccw
#1040 M_inch
#2049 type
#2201 PC1
#2202 PC2
#2218 PIT
#2219 RNG1
#2220 RNG2
#2225 MTYP
Remedy
Correct the parameter settings. Then turn the power ON again and perform zero point initialization.
(Note) To release alarm "Z70 Abs data error", enter the parameter data output when establishing the absolute
position and turn ON the power again. For the rotary axis, however, the alarm cannot be released by
entering the parameter data.
Zero point initialization: Required
Z70

Abs posn initial set illegal

Details
The zero point initialization point is not at the grid position.
Remedy
Perform the zero point initialization again.
(Note) To release alarm "Z70 Abs data error", enter the parameter data output when establishing the absolute
position and turn ON the power again. For the rotary axis, however, the alarm cannot be released by
entering the parameter data.
Zero point initialization: Required
IB-1501279-H
0001
0002
0003
0004
96
(Axis name)
(Axis name)
(Axis name)
(Axis name)