Compressed air connection
The manual stopping valve lockable in
closed position (provided by customer)
should be installed on the machine's
compressed air supply.
The supply pipe should accept a pressure of
at least 1 Mpa (10 bar) (145 psi).
• Connection diameter : rapid action hose
coupling DN 6 (0.24") for hose Ø 6/8 mm.
Nota : to avoid too big head losses, the
compressed air supply pipe should be
bigger in diameter than the coupling
diameter (DN 8 for example); in this case,
put a 6/8-8/10 adapter.
• Advised pressure : 550-700 kPa
(5,5-7 bar) (80-102 psi).
• Minimum pressure: 550 kPa (5,5 bar)
(80 psi).
• Maximum pressure : 700 kPa (7 bar)
(102 psi).
• Consumption 280 l/h.
Air compressor
Some machines are supplied with an
integrated air compressor.
At first start, it is necessary to turn off the
compressor manometer tap, wait until the
compressor reaches the pressure of 7 bars,
then re-open the valve.
•
Regularly check the oil level (every 6
months) and complete if necessary.
•
Check the cleanliness of the intake filter,
clean if necessary.
•
Purge regularly the water separator tap.
29
7
Page
7. Installation
Water separator
INSTALLATION
MANUAL
Compressed
air
D1670
Tap
D1814