Overview of functions
File name
The file name is meant for the clear identification of the
file and it must always be entered.
File header
Important information about the file is stored in the file
header. This includes e.g. the file name, the date of cre-
ation, the name of the inspector, as well as remarks, and
a memo text.
Readings
After loading the file, a reading is saved by pressing the
function key 2 (function SEND) in each case.
Comments
A comment can be saved on every measuring point.
DMS Go+
Flags
Flags are automatically added to a reading if additional
information is stored, for example the A-scan, or a min-
imum value or maximum value alarm.
You can find a list of flag symbols in Chapter 10.4 Flag
symbols, page 10-19.
A-scan
If necessary for the evaluation of measurement results,
the signal waveforms on which the readings are based
can be saved in the form of an A-scan.
N o t e
A-scans require considerably more memory
capacity than pure readings.