9.6.7 OUTPUT TIME SCHEDULE SETTING
. You can
link a T/S Code to each Output. The default T/S Code is "00" which means no T/S is applied to the
Outputs. This setting i
Press <ENT> key to l
DR: Door Relay Output T/S Code
AR: Alarm Relay Output T
T1: TTL#1 Output T/S Cod
T2:
TTL#2 Output T/S Code
BZ: Buzzer Output T/S Code
9.6.8 INPUT TIME SCHEDULE SETTING
. You can
link a T/S Code to each Input. The default T/S Code is "00" which means no T/S is applied to the
Inputs. This setting is very useful when you want to activate PIR sensor input for a Time Interval.
Press <ENT> key to link a T/S Code to the Input then enter 2digit T/S Code for each Input.
EX: EXIT Button Input T/S Code
DC: Door Contact Sensor Input T/S Code
I1: Aux Input#1 T/S Code
I2: Aux Input#2 T/S Code
TP: Tamper Switch Input T/S Code
9
.6.9 I
NPUT TYPE SETTI
. You can
program input type(00: NO, 01: NC) to each Input. The default input type is "00" which means input
is NO type.
Press <ENT> key then enter 2digit Code for each Input.
EX: EXIT Button Input type
DC: Door Contact Sensor Input type
I1: Aux Input#1 type
I2: Aux Input#2 type
TP: Tamper Switch is "00" because it is internal device.
s very useful when you want
ink a T/S Code to the Output then enter 2digit T/S Code for each Output.
/S Code
e
NG
to o
pen the door for a Ti
52
me I
nterval.

Advertisement