APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 4 of 46)
ADDR
REGISTER NAME
160D
Reserved
160E
Reserved
Ethernet Fibre Channel Status (Read/Write)
1610
Ethernet Primary Fibre Channel Status
1611
Ethernet Secondary Fibre Channel Status
Data Logger Actuals (Read Only)
1618
Data Logger Channel Count
1619
Time of Oldest Available Samples
161B
Time of Newest Available Samples
161D
Data Logger Duration
Field Unit RTD Actuals (Read Only) (8 modules)
16C0
Field RTD 1 Value
16C1
...Repeated for Field RTD 2
16C2
...Repeated for Field RTD 3
16C3
...Repeated for Field RTD 4
16C4
...Repeated for Field RTD 5
16C5
...Repeated for Field RTD 6
16C6
...Repeated for Field RTD 7
16C7
...Repeated for Field RTD 8
Field Unit Transducer Actuals (Read Only) (8 modules)
16C8
Field Transducer 1 Value
16CA
...Repeated for Field Transducer 2
16CC
...Repeated for Field Transducer 3
16CE
...Repeated for Field Transducer 4
16D0
...Repeated for Field Transducer 5
16D2
...Repeated for Field Transducer 6
16D4
...Repeated for Field Transducer 7
16D6
...Repeated for Field Transducer 8
Passwords Unauthorized Access (Read/Write Command)
2230
Reset Unauthorized Access
Field Unit Raw Data Settings (Read/Write Setting)
2460
Field Raw Data Port
2461
Field Raw Data Freeze
Remote Double-Point Status Inputs (Read/Write Setting Registers) (5 modules)
2620
Remote Double-point Status Input 1 Device
2621
Remote Double-point Status Input 1 Item
2622
Remote Double-point Status Input 1 Name
2628
Remote Double-point Status Input 1 Events
2629
... Repeated for Remote Double-point Status Input 2
2632
... Repeated for Remote Double-point Status Input 3
263B
... Repeated for Remote Double-point Status Input 4
2644
... Repeated for Remote Double-point Status Input 5
IEC 61850 GGIO5 Configuration (Read/Write Setting Registers) (16 modules)
26B0
IEC 61850 GGIO5 uinteger Input 1 Operand
26B1
IEC 61850 GGIO5 uinteger Input 2 Operand
26B2
IEC 61850 GGIO5 uinteger Input 3 Operand
26B3
IEC 61850 GGIO5 uinteger Input 4 Operand
26B4
IEC 61850 GGIO5 uinteger Input 5 Operand
26B5
IEC 61850 GGIO5 uinteger Input 6 Operand
26B6
IEC 61850 GGIO5 uinteger Input 7 Operand
26B7
IEC 61850 GGIO5 uinteger Input 8 Operand
26B8
IEC 61850 GGIO5 uinteger Input 9 Operand
26B9
IEC 61850 GGIO5 uinteger Input 10 Operand
26BA
IEC 61850 GGIO5 uinteger Input 11 Operand
GE Multilin
RANGE
UNITS
0 to 65535
0 to 65535
0 to 2
0 to 2
0 to 16
channel
0 to 4294967295
seconds
0 to 4294967295
seconds
0 to 999.9
-32768 to 32767
-32.768 to 32.767
0 to 1
0 to 7
0 to 1
1 to 32
0 to 64
1 to 64
0 to 1
---
---
---
---
---
---
---
---
---
---
---
C30 Controller System
B.4 MEMORY MAPPING
STEP
FORMAT
---
1
F500
---
1
F500
---
1
F134
---
1
F134
1
F001
1
F050
1
F050
days
0.1
F001
°C
1
F002
---
0.001
F004
---
1
F126
---
1
F244
---
1
F102
---
1
F001
---
1
F606
---
1
F205
"RemDPS Ip 1"
---
1
F102
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
DEFAULT
0
0
0 (Fail)
0 (Fail)
B
0
0
0
0
0
0
0 (No)
6 (H1a)
0 (Disabled)
1
0 (None)
0 (Disabled)
0
0
0
0
0
0
0
0
0
0
0
B-11