12.1.4 PBX Configuration—[4-1-4] Extension—Wired Extension—Flexible Button
Parameter Selection (for Time Service - Automatic/Manual)
Specifies the Time Table to be used when the Time Service Switching Mode is set to Automatic.
Value Range
Table 1–Table 32 or Table 1–Table 128
Note
The maximum number of time tables (1 per tenant) depends on the System Capacity Selection setting
made when the Easy Setup Wizard was run for the PBX. If the System Resource Type was selected, the
maximum number of tenants (and therefore, time tables) is 128. If the Standard Type or IP-Extension
Type was selected, the maximum number of tenants is 32. For details, refer to "5.4.1 Easy Setup
Wizard" in the Installation Manual.
Maintenance Console Location
12.1.4 PBX Configuration—[4-1-4] Extension—Wired Extension—Flexible Button
Feature Guide References
5.1.4 Time Service
Parameter Selection (for SDN)
Specifies the delayed ringing setting for calls arriving at an SDN button.
Value Range
Immediate, 1 Ring, 2 Rings, 3 Rings, 4 Rings, 5 Rings, 6 Rings, No Ring
Maintenance Console Location
12.1.4 PBX Configuration—[4-1-4] Extension—Wired Extension—Flexible Button
Feature Guide References
2.9.1 Primary Directory Number (PDN)/Secondary Directory Number (SDN) Extension
Extension Number (for DSS)
Specifies the number of an extension to be accessed.
Value Range
Max. 5 digits (consisting of 0–9)
Maintenance Console Location
12.1.4 PBX Configuration—[4-1-4] Extension—Wired Extension—Flexible Button
Extension Number (for ICD Group)
Specifies the floating extension number of an incoming call distribution group to be accessed.