ASSEMBLING AND ADJUSTMENTS

Install the power unit

Place the power unit on the workplace, making sure that it is standing on a stable surface and that it is protected from
water spray.

Type of installation

When the power unit is connected to an electrical installation protected by a Residual Current Circuit-Breaker this must
be of type B (fig.1), whereas an installation protected by a type A Residual Current Circuit-Breaker must support
connection to its primary side, i.e. upstream of the Residual Current Circuit-Breaker (fig. 2).
Local expertise may be able to recommend safe alternatives to the above connections. If you encounter a situation where
you are uncertain you should allways ask an expert. Contact your dealer or your service workshop.
Fig. 1
Fig. 2
A
A
C
B
D
D
D
D
E
E
J
J
F
F
G
G
H
H
A - Power supply
B - Residual-current device type B
C - Residual-current device type A
D - Connector
E - Built in residual-current device type B
F - Other equipment
G - Power pack
H - Power tool
J - PP65
English – 7