Processing details
• These instructions convert the 16-bit binary data (0 to 9999) in the device specified by (s) to BCD 4-digit data, and store the
converted data in the device specified by (d).
15
14
13
12
2
2
2
2
2
(s)
BIN 9999
0
0
1
0
(1)
×10
3
8
4
2
1
(d)
BCD 9999
1
0
0
1
(1) Set 0s.
Operation error
Error code
Description
(SD0)
3401H
Data in the device specified by (s) is out of the range, 0 to 9999.
11
10
9
8
7
6
5
4
2
2
2
2
2
2
2
0
1
1
1
0
0
0
0
BCD
×10
×10
2
1
8
4
2
1
8
4
2
1
1
0
0
1
1
0
0
1
3
2
1
0
2
2
2
2
1
1
1
1
×10
0
8
4
2
1
1
0
0
1