Samsung Officeserv 7100 Technical Manual page 64

Hide thumbs Also See for Officeserv 7100:
Table of Contents

Advertisement

OfficeServ 7100
TECHNICAL MANUAL
2. Each switch must be given a unique multi-digit ID number that does not conflict with
the North American Dialing Plan. e.g. one switch is ID 001, a second is ID 002, a
third is 003, etc. The digits star (*) and pound (#) cannot be used in switch ID
numbers, This information is entered in MMC 820.
MMC 820. System Link ID
• Link ID : System node ID to distinguish systems in the network. It can not be
duplicated. Assign a unique node ID for each system in the network including
one for the node you are on ("SELF").
• Signal G/W: For VoIP networking, all IP addresses for the connected systems
should be assigned. The IP address for the current node should also be
assigned for SELF.
• IP Type : IP type connected through VoIP networking should be assigned.
• Assign the id for all other nodes
• When a call is placed on the networking trunk, the system usually regards the
number as node number + station number. If the node number is identified with
the self node number, the system removes the node number and places the call
according to MMC 714. If not, forwards the call to another system according to
MMC 710 (Tandem Call). If there is no identified number, the system regards it
as the station number and places the call according to MMC 714.
3. Determine the extension number range(s) for each switch:
Switch 001 is 2001 → 2199
e.g.
Switch 002 is 2200 → 2299
Switch 003 is 2300 → 2399
Determine the group number ranges for each switch:
001 is 5000 → 5049
e.g.
002 is 5100 → 5149
003 is 5200 → 5249
4. Determine the network LCR access codes from the information in items 2 and 3
above. These are the common leading digits for the station and group numbers in
the other switches.
e.g. for switch 001 this would be 22 (so 22XX extensions can be called), 23 (so
23XX extensions can be called), These are for stations in the other systems, 51 (so
51XX groups can be called) and 52 (so 52XX groups can be called), These are for
station groups in other systems.