GE C60 Instruction Manual page 231

Multilin breaker management relay ur series
Hide thumbs Also See for C60:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 3 of 29)
ADDR
REGISTER NAME
1575
...Repeated for module number 10
1579
...Repeated for module number 11
157D
...Repeated for module number 12
1581
...Repeated for module number 13
1585
...Repeated for module number 14
1589
...Repeated for module number 15
158D
...Repeated for module number 16
Ethernet Fibre Channel Status (Read/Write)
1610
Ethernet Primary Fibre Channel Status
1611
Ethernet Secondary Fibre Channel Status
Data Logger Actuals (Read Only)
1618
Data Logger Channel Count
1619
Time of oldest available samples
161B
Time of newest available samples
161D
Data Logger Duration
Source Current (Read Only) (6 modules)
1800
Phase A Current RMS
1802
Phase B Current RMS
1804
Phase C Current RMS
1806
Neutral Current RMS
1808
Phase A Current Magnitude
180A
Phase A Current Angle
180B
Phase B Current Magnitude
180D
Phase B Current Angle
180E
Phase C Current Magnitude
1810
Phase C Current Angle
1811
Neutral Current Magnitude
1813
Neutral Current Angle
1814
Ground Current RMS
1816
Ground Current Magnitude
1818
Ground Current Angle
1819
Zero Sequence Current Magnitude
181B
Zero Sequence Current Angle
181C
Positive Sequence Current Magnitude
181E
Positive Sequence Current Angle
181F
Negative Sequence Current Magnitude
1821
Negative Sequence Current Angle
1822
Differential Ground Current Magnitude
1824
Differential Ground Current Angle
1825
Reserved (27 items)
1840
...Repeated for module number 2
1880
...Repeated for module number 3
18C0
...Repeated for module number 4
1900
...Repeated for module number 5
1940
...Repeated for module number 6
Source Voltage (Read Only) (6 modules)
1A00
Phase AG Voltage RMS
1A02
Phase BG Voltage RMS
1A04
Phase CG Voltage RMS
1A06
Phase AG Voltage Magnitude
1A08
Phase AG Voltage Angle
1A09
Phase BG Voltage Magnitude
1A0B
Phase BG Voltage Angle
1A0C
Phase CG Voltage Magnitude
GE Multilin
RANGE
0 to 2
0 to 2
0 to 16
0 to 4294967295
0 to 4294967295
0 to 999.9
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
---
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
C60 Breaker Management Relay
B.3 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F134
---
1
F134
CHNL
1
F001
seconds
1
F050
seconds
1
F050
DAYS
0.1
F001
A
0.001
F060
A
0.001
F060
A
0.001
F060
A
0.001
F060
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
---
---
F001
V
0.001
F060
V
0.001
F060
V
0.001
F060
V
0.001
F060
°
0.1
F002
V
0.001
F060
°
0.1
F002
V
0.001
F060
DEFAULT
B
0 (Fail)
0 (Fail)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
B-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents