PROMPTS
Flt Rel ON Y/N
27
(N)_
Tamper Rpt Y/N
28
(Y)_
29
Lynx Panic Y/N
(N)_
4204/
ZONE
ENTRY
2-4204
TRIG.
Section 3: Programming the 7847i-E
OPTIONS
During normal system operation the open
[Y], [N]
collector fault output will change states (open or
ground) on a fault condition. The change of state
depends on whether (Y) or (N) is used during
programming.
Choosing Flt Rel ON (Y),
Choosing Flt Rel ON (N),
This mode is lower power consumption.
UL/ULC NOTE: Must be set to "Y."
[Y], [N]
Sends a tamper report on zone 8 when the
module detects a tamper condition. A tamper
restore is automatically sent when the tamper
condition clears.
UL/ULC NOTE: Must be "Y" for commercial
burglary
Applies only if used with control communication
[Y], [N]
device (LRR) trigger connected to the module's
zone terminal.
Reports a Panic alarm on zone 3 when the
module detects a single pulse on zone 1.
No restores are generated for a Panic alarm.
DESCRIPTION
Tamper *
Loss of Network Connectivity *
Message Communication Failure
Device Not Registered
*Fault must be enabled in programming
for these conditions (tamper & loss of
network) to trigger the fault output
Provides a ground during normal
operation.
Provides an open during a fault.
"Failsafe mode" (if the radio loses power,
the fault output opens, de-energizing the
relay)
Provides an open during normal
operation.
Provides a ground during a fault
condition.