No
Status
.
-
No defects
1
F-thermistor system defect
2
R-thermistor system defect
3
DEF-thermistor system defect
Outside temperature-thermistor
4
system defect
5
Defrost defect
6
F fan motor system defect
7
C fan motor system defect
8
R fan motor system defect
Ionizer (Plasmacluster) system
9
defect
10
LCD Display communication defect
11
F-thermistor system defect history
12
R-thermistor system defect history
DEF-thermistor system defect his-
13
tory
Outside temperature-thermistor
14
system defect history
15
F fan motor system defect history
16
C fan motor system defect history
17
R fan motor system defect history
Ionizer (Plasmacluster) electrifying
18
defect history
19
F-room high temperature history
20
R-room high temperature history
Buzzer:
=0.5 sec ON/0.5 sec OFF,
Buzzer
LCD
Display
None
- - - -
EE 01
EE 02
Defect of each thermistor, short circuit/wire breakage of ther-
EE 03
mistor wiring and defect of main PWB
EE 04
Wire breakage of fuse•defrost heater, defect of main PWB
EE 07
(120-minute defrosting has been occurred continuously 2 times
within the past 48 hours.)
EE 08
EE 09
Defect of each fan motor, fan-lock and defect of wiring/main
PWB
EE 10
(When fan motor is ON, over current or no current is detected.)
EE 11
Short circuit/wire breakage of wiring and defect of LCD or main
EE 12
PWB (Communication with LCD PWB has been abnormal over
3 times within the past 48 hours.)
EH 61
EH 62
Defect of thermistor system has been occurred over 1 minute
EH 63
continuously within the past 48 hours.
EH 64
EH 66
Defect of fan motor has been occurred over 3 times continu-
EH 67
ously within the past 48 hours.
EH 68
Defect of Ionizer (Plasmacluster) electrifying has been
EH 72
occurred over 3 times continuously within the past 48 hours.
Temperature of F-thermistor has been reached over -10°C con-
EH 76
tinuously for 6 hours or more within the past 48 hours. (except
right after the installation)
Temperature of R-thermistor has been reached over +10°C
EH 77
continuously for 6 hours or more within the past 48 hours.
(except right after the installation)
=2 sec ON/0.5 sec OFF
9 – 2
SJF800SPSL
Content
Correspon-
dence
method