Panasonic KX-TDE100 Product Catalog page 16

Converged ip-pbx systems, voice processing systems and acd reporting system
Hide thumbs Also See for KX-TDE100:
Table of Contents

Advertisement

It is necessary to select the proper power supply for the system in accordance with the type and number of extensions that are connected to
the system. There are 3 power supply options; S = Small, M = Medium and L = Large. To calculate the size of the power supply required for
your application, you must determine the type of telephone extensions you plan to use. Then using the telephone equipment power factor
"B" portion of the chart below, calculate the point value for each and add up all the points. Using the Power Supply Maximum Power Factor
"A" portion of the chart below, match up the points calculated with the correct power supply. The power supply value must be greater than
the total points calculated for the telephone equipment. (When in doubt use the larger power supply.)
Power Supply Model
Maximum Power Factor
KX-T7400 & KX-T7200 Digital Series (KX-TD Digital System Phones)
KX-T7000, KX-T7300, KX-T7700 Series and DSS Consoles (KX-T & KX-TA Hybrid System Phones)
SLT* Cards
(Single Line Telephones)
* Calculation must be based on the number of cards, not the number of telephones.
Units, Weights and Specifications subject to change.
KX-TDE100 & KX-TDE200 POWEr SUPPLY
A - Power Supply Maximum Power Factors
TDE100
KX-TDA0108 (S Type)
KX-TDA0104 (M Type)
64
B - Telephone Equipment Power Factor
Telephone Equipment
T7600 Digital Series (KX-TDA Digital System Phones)
IP Telephones (KX-NT SERIES)
SIP Extensions
Cell Station (KX-T0151, KX-T0155, & KX-TDA0152)
High density cell station (1 unit)
KX-TVA & KX-NCV Voice Mail Port Connection (2 ch)
CHArT #1
KX-TDA0104 (M Type)
128
SLC8
SLC16
MSLC16
DHLC8
16
TDE200
KX-TDA0103 (L Type)
128
512
Point Value
For Each
1
4
4
0
0
8
16
16
8
4
8
1
version 1.2