Siemens SIMATIC S5 Manual page 121

Ip 267 stepper motor controller
Hide thumbs Also See for SIMATIC S5:
Table of Contents

Advertisement

IP 267
OB 1
SEGMENT 1
0000
0000
:A
I
0.7
0001
:S
F
101.6
0002
:
0003
:A
F
104.7
0004
:R
F
104.7
0005
:BEC
0006
:
0007
:A
F
101.6
0008
:JC
FB
50
0009 NAME :PARAM-RP
000A
:
000B
:O
F
104.7
000C
:O
F
101.6
000D
:BEC
000E
:
000F
:
0010
:
0011
:
0012
:
0013
:A
I
0.0
0014
:S
F
101.0
0015
:
0016
:
0017
:A
F
103.7
0018
:R
F
103.7
0019
:BEC
001A
:
001B
:A
F
101.0
001C
:JC
FB
51
001D NAME :VPROG
001E
:
001F
:
0020
:
0021
:
0022
:BE
EWA 4NEB 812 6061-02a
Application Examples
LEN=40
FLAG F 101.6 CAN ALSO BE SET
IN THE WARM RESTART OBS
"BASIC STATUS" ROUTINE
OF THE IP 267 ON WARM RESTART
ROUTINE FOR STARTING
THE USER PROGRAM
WITH FLAG F 103.7 THE PROGRAM WAITS
FOR THE POSITIONING JOB
TO BE EXECUTED
BEFORE SWITCHING TO "NEUTRAL" MODE
(CPU WAIT CYCLE)
ABS
PAGE
1
6-45
6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents