1-3 STANDARD NOTES FOR SERVICING

General Note: "CBA" is an abbreviation for
"Circuit Board Assembly."

1-3-1 Circuit Board Indications

a. The output pin of the 3 pin Regulator ICs is indi-
cated as shown.
Top View
Out
In
b. For other ICs, pin 1 and every fifth pin are indicated
as shown.
Pin 1
c. The 1st pin of every male connector is indicated as
shown.
Pin 1

1-3-2 Instructions for Connectors

1. When you connect or disconnect the FFC (Flexible
Foil Connector) cable, be sure to first disconnect
the AC cord.
2. FFC (Flexible Foil Connector) cable should be
inserted parallel into the connector, not at an angle.
FFC Cable
Connector
* Be careful to avoid a short circuit.

1-3-3 Pb (Lead) Free Solder

When soldering, be sure to use the Pb free solder.
Bottom View
Input
5
10
CBA
1-3-4 Instructions for Handling
Semi-conductors
Electrostatic breakdown of the semi-conductors may
occur due to a potential difference caused by electro-
static charge during unpacking or repair work.
1. Ground for Human Body
Be sure to wear a grounding band (1MΩ) that is prop-
erly grounded to remove any static electricity that may
be charged on the body.
2. Ground for Workbench
(1) Be sure to place a conductive sheet or copper plate
with proper grounding (1MΩ) on the workbench or
other surface, where the semi-conductors are to be
placed. Because the static electricity charge on
clothing will not escape through the body ground-
ing band, be careful to avoid contacting semi-con-
ductors with your clothing.
<Incorrect>
<Correct>
1MΩ
1-4
CBA
Grounding Band
1MΩ
CBA
Conductive Sheet or
Copper Plate