CHAPTER 2. MMC Programming
[119] CALLER ID DISPLAY
Allows the technician to set the individual station display preference on a per-station basis.
Caller ID or CLI can be selected to either show the name, number first, or no display de-
pending on the type of call. Caller ID or CLI displays have the following options:
No
0
NO DISPLAY
1
NUMBER FIRST
2
NAME FIRST
DEFAULT DATA
NUMBER FIRST
ACTION
1. Press Transfer button and enter 119.
Display shows first station:
2. Enter station number (e.g., 205)
OR
Press Volume button to select station and press Right
Soft button
OR
Select all stations
3. Dial display option 0, 1 or 2 (e.g., 2)
OR
Press Volume button to select option and press
Right or Left Soft button to return to step 2.
4. Press Transfer button to save and exit.
OR
Press Speaker button to save and advance to
next MMC.
RELATED ITEMS
MMC 312
MMC 608
MMC 728
Samsung Business Communications
Type
No Caller ID or CLIP data will be displayed.
The Caller ID or CLIP number received from the Central Office
will be displayed first.
The Caller ID or CLIP name received will be displayed first.
In the case of CLIP the number must be programmed in the
CLIP translation table(MMC 728). CLIP does not provide
names.
ALLOW CALLER ID
ASSIGN REVIEW BLOCK
CID TRANSLATION TABLE
OfficServ 7200 Programming Guide
Description
DISPLAY
[201] CID DISP
NUMBER FIRST
[205] CID DISP
NUMBER FIRST
[ALL] CID DISP
NUMBER FIRST
[205] CID DISP
NAME FIRST